Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Dec;10(4):657-62.
doi: 10.1007/s11552-015-9762-y. Epub 2015 Jul 7.

Anatomic relationships in distal radius bridge plating: a cadaveric study

Affiliations

Anatomic relationships in distal radius bridge plating: a cadaveric study

Jason Dahl et al. Hand (N Y). 2015 Dec.

Abstract

Background: Two separate approaches have been described for radiocarpal spanning internal fixation for high-energy distal radius fractures with metaphyseal extension. To our knowledge, relevant anatomic relationships and structures at risk for iatrogenic injury have not been identified in the literature.

Methods: Twelve fresh frozen cadaver arms were randomized to fixation with a dorsal radiocarpal spanning plate using one of two techniques: (1) index finger metacarpal fixation (index group) or (2) middle finger metacarpal fixation (middle group). Cadaveric dissection and relevant anatomic relationships were assessed in relation to the plate.

Results: Superficial branches of the radial sensory nerve were in contact with the index group plate in all specimens, while no contact occurred in the middle group specimens. No extensor digitorum comminus (EDC) middle extensor tendons contacted the plate in the index group; an average of 10 cm of plate contact was seen in the middle group. The extensor pollicis longus (EPL) tendon contacted the plate in both the index and middle groups for an average distance of 12.4 and 25.5 mm, respectively. One complication [EPL and extensor indicis proprius (EIP) entrapment] was observed in the middle finger metacarpal group.

Conclusion: Mounting the dorsal bridge plate to the index finger metacarpal places the superficial branches of the radial sensory nerve at risk during dissection, while mounting the plate to the middle finger metacarpal leads to a greater degree of tendon-plate contact.

Keywords: Bridge plate; Cadaver; Distal radius fracture; Distraction plate.

PubMed Disclaimer

Figures

Fig. 1
Fig. 1
Superficial sensory branches of the radial nerve crossing the plate in an index group specimen
Fig. 2
Fig. 2
Finger extensor tendon plate contact in a middle group specimen
Fig. 3
Fig. 3
EPL (beneath retractor) and EIP entrapment in a middle group specimen

References

    1. Akmaz I, Pehlivan O, Kiral A, Solakoğlu C. Arpacioğlu O [Short-term results of external fixation of unstable distal radial fractures] Acta Orthop Traumatol Turc. 2003;37:126–32. - PubMed
    1. Azzopardi T, Ehrendorfer S, Coulton T, Abela M. Unstable extra-articular fractures of the distal radius: a prospective, randomised study of immobilisation in a cast versus supplementary percutaneous pinning. J Bone Joint Surg (Br) 2005;87:837–40. doi: 10.1302/0301-620X.87B6.15608. - DOI - PubMed
    1. Becton JL, Colborn GL, Goodrich JA. Use of an internal fixator device to treat comminuted fractures of the distal radius: report of a technique. Am J Orthop (Belle Mead NJ) 1998;27:619–23. - PubMed
    1. Bishay M, Aguilera X, Grant J, Dunkerley DR. The results of external fixation of the radius in the treatment of comminuted intraarticular fractures of the distal end. J Hand Surg (Br) 1994;19:378–83. doi: 10.1016/0266-7681(94)90094-9. - DOI - PubMed
    1. Burke EF, Singer RM. Treatment of comminuted distal radius with the use of an internal distraction plate. Tech Hand Up Extrem Surg. 1998;2:248–52. doi: 10.1097/00130911-199812000-00004. - DOI - PubMed

LinkOut - more resources