Automated differential leukocyte counts
- PMID: 2658725
Automated differential leukocyte counts
Abstract
Automated differential counts have the advantage of precision, efficiency, safety, and economy. They could potentially serve effectively in 90 percent of patients with normal counts or in 75 percent of patients with anemia only (64 percent of the total in this study). Even patients with increased white blood cell counts and major population shifts (toward granulocytes or lymphocytes) could be followed with automated differential counts. Such a tactic would decrease turnaround time for results, be less expensive, and reduce exposure of technologists to direct contact with patients' blood. However, presently available instruments fail to detect patients' blood samples with small numbers of abnormal cells, e.g., blasts in early relapse of acute leukemia, atypical lymphocytes in viral diseases such as infectious mononucleosis, eosinophils in allergic or parasitic disease, and band forms in early infectious diseases. Clinical judgment should be used in selectively ordering manual differential counts for these patients. While automated differential counts can be very useful in screening general medical and surgical patients in the ambulatory setting, in referral centers where hematologic abnormalities are more prevalent, the manual differential count and further examination of a smear is particularly necessary at least on initial presentation. Selective manual differential counts may improve efficiency, economy, and safety while not compromising patient care. Further studies of the correlation of clinical disease with automated differential counts are necessary.
Similar articles
-
Automated leucocyte differentials in 292 patients with leucopenia: an evaluation of the Abbott CELL-DYN 3500 (CD3500) haematology analyser.Clin Lab Haematol. 1996 Dec;18(4):253-9. Clin Lab Haematol. 1996. PMID: 9054698
-
Automated five-part white blood cell differential counts. Efficiency of software-generated white blood cell suspect flags of the hematology analyzers Sysmex SE-9000, Sysmex NE-8000, and Coulter STKS.Arch Pathol Lab Med. 1997 Jun;121(6):573-7. Arch Pathol Lab Med. 1997. PMID: 9199621
-
[Studies on the efficient application by STKS and 8200].Rinsho Byori. 1992 Jun;40(6):577-85. Rinsho Byori. 1992. PMID: 1513029 Japanese.
-
[Further evolution and leukocyte differential using an automated blood cell counter].Rinsho Byori. 1995 Sep;43(9):925-30. Rinsho Byori. 1995. PMID: 7474456 Review. Japanese.
-
Peripheral blood film review. The demise of the eyecount leukocyte differential.Clin Lab Med. 2002 Mar;22(1):279-97. doi: 10.1016/s0272-2712(03)00075-1. Clin Lab Med. 2002. PMID: 11933579 Review.
Cited by
-
Comparison of Two Methods for the Determination of the Effects of Ionizing Radiation on Blood Cell Counts in Mice.Int J Biomed Sci. 2012 Mar 15;8(1):7-15. Int J Biomed Sci. 2012. PMID: 23450807 Free PMC article.