Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Sep;23(3):130-4.
doi: 10.1177/0969141315609634. Epub 2015 Nov 19.

Interval cancers using a quantitative faecal immunochemical test (FIT) for haemoglobin when colonoscopy capacity is limited

Affiliations

Interval cancers using a quantitative faecal immunochemical test (FIT) for haemoglobin when colonoscopy capacity is limited

Jayne Digby et al. J Med Screen. 2016 Sep.

Abstract

Objectives: Quantitative faecal immunochemical tests (FIT) for faecal haemoglobin (f-Hb) in colorectal cancer (CRC) screening pose challenges when colonoscopy is limited. For low positivity rates, high f-Hb concentration cut-offs are required, but little is known about interval cancer (IC) proportions using FIT. We assessed IC proportions using an 80 µg Hb/g cut-off.

Methods: In two NHS Boards in the Scottish Bowel Screening Programme, f-Hb was estimated for 30,893 participants aged 50-75, of whom 753 participants with f-Hb ≥ 80 µg Hb/g were referred for colonoscopy. ICs, defined as CRC within two years of a negative result, were identified from the Scottish Cancer Registry.

Results: There were 31 ICs and 30 screen-detected (SD) CRCs, an IC proportion of 50.8% (48.4% for men, 53.3% for women). CRC site distribution was similar between ICs and SD, but ICs were later stage (46.7% and 33.3%, Dukes' stages C and D, respectively). Of 31 ICs, 23 had f-Hb < 10 µg Hb/g, including six with undetectable f-Hb. A f-Hb cut-off of 10 µg Hb/g would have raised the positivity rate from 2.4% to 9.4%, increased colonoscopy requirement from 753 to 2147, and reduced the IC proportion to 38.3%.

Conclusions: The IC proportion was similar to that seen with guaiac-based FOBT. The later stage distribution of ICs highlights the benefits of lower f-Hb cut-offs, but with 19.4% of ICs having undetectable f-Hb, some cancers would have been missed, even with drastic reduction in the f-Hb cut-off.

Keywords: Colorectal cancer; faecal haemoglobin; faecal immunochemical test; faecal occult blood test; interval cancers.

PubMed Disclaimer

LinkOut - more resources