Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2016 Jan;71(1):48-57.
doi: 10.1016/j.crad.2015.09.011. Epub 2015 Nov 17.

An efficacy and safety comparison between different stentriever designs in acute ischaemic stroke: a systematic review and meta-analysis

Affiliations
Meta-Analysis

An efficacy and safety comparison between different stentriever designs in acute ischaemic stroke: a systematic review and meta-analysis

R Grech et al. Clin Radiol. 2016 Jan.

Abstract

Aim: To assess the recanalisation rates and long-term functional outcomes of the Solitaire and Trevo devices; to compare these results to those from the Solitaire With the Intention For Thrombectomy (SWIFT) trial and TREVO 2 studies; and to assess for statistical differences in the outcomes between the two devices.

Materials and methods: A systematic review and meta-analysis of studies that utilised stentrievers in the treatment of acute ischaemic stroke was conducted. The results were compared to those of the SWIFT and TREVO 2 trials and outcome differences between Trevo (Stryker, Kalamazoo, Michigan, USA) and Solitaire (ev3/Covidien, Irvine, California, USA) were analysed statistically.

Results: Solitaire had a lower mortality rate compared to Trevo (16.2% [95% confidence interval {CI}: 13.1%, 19.8%] versus 22.2% [95% CI: 10.8%, 40.2%]) and achieved a higher rate of functional independence (52.1% [95% CI: 46.3%, 57.8%] versus 47.6% [95% CI: 36.7%, 58.8%]). Statistical tests, however, failed to demonstrate significant differences in either functional outcomes or 3-month mortality rates. No significant differences were noted in weighted mean recanalisation rates between the Solitaire and Trevo groups.

Conclusion: Stentrievers achieve a high rate of recanalisation and functional independence in acute ischaemic stroke and have a relatively good safety profile. No significant differences in functional outcomes, mortality, and symptomatic intra-cranial haemorrhage could be demonstrated between two popular stentrievers designs, namely Trevo and Solitaire.

PubMed Disclaimer

LinkOut - more resources