Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2015 Nov 18;6(10):783-94.
doi: 10.5312/wjo.v6.i10.783.

Collecting shoulder kinematics with electromagnetic tracking systems and digital inclinometers: A review

Affiliations
Review

Collecting shoulder kinematics with electromagnetic tracking systems and digital inclinometers: A review

Daniel C Hannah et al. World J Orthop. .

Abstract

The shoulder complex presents unique challenges for measuring motion as the scapula, unlike any other bony segment in the body, glides and rotates underneath layers of soft tissue and skin. The ability for clinicians and researchers to collect meaningful kinematic data is dependent on the reliability and validity of the instrumentation utilized. The aim of this study was to review the relevant literature pertaining to the reliability and validity of electromagnetic tracking systems (ETS) and digital inclinometers for assessing shoulder complex motion. Advances in technology have led to the development of biomechanical instrumentation, like ETS, that allow for the collection of three-dimensional kinematic data. The existing evidence has demonstrated that ETS are reliable and valid instruments for collecting static and dynamic kinematic data of the shoulder complex. Similarly, digital inclinometers have become increasingly popular among clinicians due to their cost effectiveness and practical use in the clinical setting. The existing evidence supports the use of digital inclinometers for the collection of shoulder complex kinematics as these instruments have been demonstrated to yield acceptable reliability and validity. While digital inclinometers pose a disadvantage to ETS regarding accuracy, precision, and are limited to two-dimensional and static measurements, this instrument provides clinically meaningful data that allow clinicians and researchers the ability to measure, monitor, and compare shoulder complex kinematics.

Keywords: Biomechanics; Glenohumeral; Kinematics; Reliability; Scapulothoracic; Validity.

PubMed Disclaimer

References

    1. Kibler WB, Sciascia A. Current concepts: scapular dyskinesis. Br J Sports Med. 2010;44:300–305. - PubMed
    1. Inman VT, Saunders JB, Abbott LC. Observations on the function of the shoulder joint. J Bone Joint Surg Am. 1944;26:1–30.
    1. Poppen NK, Walker PS. Normal and abnormal motion of the shoulder. J Bone Joint Surg Am. 1976;58:195–201. - PubMed
    1. McClure PW, Michener LA, Sennett BJ, Karduna AR. Direct 3-dimensional measurement of scapular kinematics during dynamic movements in vivo. J Shoulder Elbow Surg. 2001;10:269–277. - PubMed
    1. de Groot JH. The scapulo-humeral rhythm: effects of 2-D roentgen projection. Clin Biomech (Bristol, Avon) 1999;14:63–68. - PubMed

LinkOut - more resources