Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2016 Apr;35(2):93-102.
doi: 10.1016/j.accpm.2015.08.003. Epub 2015 Nov 19.

The use of static and dynamic haemodynamic parameters before volume expansion: A prospective observational study in six French intensive care units

Affiliations
Observational Study

The use of static and dynamic haemodynamic parameters before volume expansion: A prospective observational study in six French intensive care units

Sébastien Preau et al. Anaesth Crit Care Pain Med. 2016 Apr.

Abstract

Objective: The aim of the present study was to determine the use of static and dynamic haemodynamic parameters for predicting fluid responsiveness prior to volume expansion (VE) in intensive care unit (ICU) patients with systemic inflammatory response syndrome (SIRS).

Methods: We conducted a prospective, multicentre, observational study in 6 French ICUs in 2012. ICU physicians were audited concerning their use of static and dynamic haemodynamic parameters before each VE performed in patients with SIRS for 6 consecutive weeks.

Results: The median volume of the 566 VEs administered to patients with SIRS was 1000mL [500-1000mL]. Although at least one static or dynamic haemodynamic parameter was measurable before 99% (95% CI, 99%-100%) of VEs, at least one them was used in only 38% (95% CI, 34%-42%) of cases: static parameters in 11% of cases (95% CI, 10%-12%) and dynamic parameters in 32% (95% CI, 30%-34%). Static parameters were never used when uninterpretable. For 15% of VEs (95% CI, 12%-18%), a dynamic parameter was measured in the presence of contraindications. Among dynamic parameters, respiratory variations in arterial pulse pressure (PPV) and passive leg raising (PLR) were measurable and interpretable before 17% and 90% of VEs, respectively.

Conclusions: Haemodynamic parameters are underused for predicting fluid responsiveness in current practice. In contrast to static parameters, dynamic parameters are often incorrectly used in the presence of contraindications. PLR is more frequently valid than PPV for predicting fluid responsiveness in ICU patients.

Keywords: Inflammation; Intensive care; Passive leg raising; Respiratory variations; SIRS; Sepsis; Systemic inflammatory response syndrome.

PubMed Disclaimer

Publication types

Substances

LinkOut - more resources