. 2015 Oct 23:9:54.
doi: 10.14444/2054. eCollection 2015.

Fluoroscopy-guided pedicle screw accuracy with a mini-open approach: a tomographic evaluation of 470 screws in 125 patients

Affiliations

Fluoroscopy-guided pedicle screw accuracy with a mini-open approach: a tomographic evaluation of 470 screws in 125 patients

José Antonio Soriano-Sánchez et al. Int J Spine Surg. .

Abstract

Background: Transpedicular screws are currently placed with open free hand and minimally invasive techniques assisted with either fluoroscopy or navigation. Screw placement accuracy had been investigated with several methods reaching accuracy rates from 71.9% to 98.8%. The objective of this study was to assess the accuracy and safety for 2-D fluoroscopy-guided screw placement assisted with electrophysiological monitoring and the inter-observer agreement for the breach classification.

Methods: A retrospective review was performed on 125 consecutive patients who underwent minimally invasive transforaminal lumbar interbody fusion and transpedicular screws placement between the levels of T-12 and S-1. Screw accuracy was evaluated using a postoperative computed tomography by three independent observers. Pedicle breach was documented when there was a violation in any direction of the pedicle. Inter-observer agreement was assessed with the Kappa coefficient.

Results: A total of 470 transpedicular screws were evaluated between the levels of T-12 and S-1. In 57 patients the instrumentation was bilateral and in 68 unilateral. A substantial degree of agreement was found between the observers AB (κ=0.769) and A-C (κ=0.784) and almost perfect agreement between observers B-C (κ=0.928). There were a total of 427.33 (90.92%) screws without breach, 39.33 (8.37%) minor breach pedicles and 3.33 (0.71%) major breach pedicles. The pedicle breach rate was 9.08% Trajectory pedicle breach percentages were as follows: minor medial pedicle breach 4.68%, minor lateral pedicle breach 3.47%, minor inferior pedicle breach 0.22%, and major medial breach 0.70%. No intraoperative instrumentation-related or postoperative clinical complications were encountered and no surgical revision was needed.

Conclusions: Our study demonstrated a high accuracy (90.2%) for 2-D fluoroscopy-guided pedicle screw using electromonitoring. Only 0.71% of the 470 screws had a major breach. Knowing the radiological spine pedicle anatomy and the correct interpretation of EMG are the key factors for this technique.

Keywords: Accuracy; Computed tomography; Minimally invasive; electromonitoring; fluoroscopy; mini-open; pedicle screw.

PubMed Disclaimer

Figures

Fig. 1
Fig. 1
Postoperative axial CT image depicting the classification used for accuracy assessment. A. No breach. B. Minor breach ≤2 mm. C. Major breach ≥3 mm.
Fig. 2
Fig. 2
Fluoroscopic-guided screw placement technique using the true AP and lateral views.
Fig. 3
Fig. 3
Stacked bar graphdemonstrating the number of pedicles without pedicle breach, minor pedicle breach and major pedicle breach at each level.

References

    1. Puvanesarajah V, Liauw JA, Lo SF, Lina IA, Witham TF. Techniques and accuracy of thoracolumbar pedicle screw placement. World journal of orthopedics. 2014;5:112–23. - PMC - PubMed
    1. Kosmopoulos V, Schizas C. Pedicle screw placement accuracy: a meta-analysis. Spine. 2007;32:E111–20. - PubMed
    1. Matsuzaki H, Tokuhashi Y, Matsumoto F, Hoshino M, Kiuchi T, Toriyama S. Problems and solutions of pedicle screw plate fixation of lumbar spine. Spine. 1990;15:1159–65. - PubMed
    1. Donovan DJ, Polly DW, Jr, Ondra SL. The removal of a transdural pedicle screw placed for thoracolumbar spine fracture. Spine. 1996;21:2495–8. discussion 9. - PubMed
    1. Lopera JE, Restrepo CS, Gonzales A, Trimmer CK, Arko F. Aortoiliac vascular injuries after misplacement of fixation screws. The Journal of trauma. 2010;69:870–5. - PubMed

LinkOut - more resources