Fluence to local skin absorbed dose and dose equivalent conversion coefficients for monoenergetic positrons using Monte-Carlo code MCNP6
- PMID: 26623930
- DOI: 10.1016/j.apradiso.2015.11.029
Fluence to local skin absorbed dose and dose equivalent conversion coefficients for monoenergetic positrons using Monte-Carlo code MCNP6
Abstract
Conversion coefficients fluence to local skin equivalent dose, as introduced in ICRP Publication 116, 2010, are calculated for positrons of energies ranging from 10 keV to 10 MeV using the code MCNP6. Fluence to dose equivalent conversion coefficients H'(0.07,0°)/Φ are calculated for positrons of energy ranging between 20 keV and 10 MeV. A comparison between operational dose quantity H'(0.07,0°) and the Local-Skin equivalent Dose shows an overall good agreement between these two quantities, except between 60 keV and 100 keV.
Keywords: Local-Skin equivalent Dose; MCNP6; Positrons; Skin dose.
Copyright © 2015 Elsevier Ltd. All rights reserved.
Similar articles
-
CALCULATION OF SKIN DOSE DUE TO BETA CONTAMINATION USING THE NEW QUANTITY OF THE ICRP 116: THE 'LOCAL SKIN DOSE'.Radiat Prot Dosimetry. 2017 Nov 1;176(4):365-379. doi: 10.1093/rpd/ncx019. Radiat Prot Dosimetry. 2017. PMID: 28338860
-
Deuterons at energies of 10 MeV to 1 TeV: conversion coefficients for fluence-to-absorbed dose, equivalent dose, effective dose and gray equivalent, calculated using Monte Carlo radiation transport code MCNPX 2.7.C.Radiat Prot Dosimetry. 2011 Jan;143(1):17-26. doi: 10.1093/rpd/ncq317. Epub 2010 Oct 27. Radiat Prot Dosimetry. 2011. PMID: 20980368
-
Tritons at energies of 10 MeV to 1 TeV: conversion coefficients for fluence-to-absorbed dose, equivalent dose, effective dose and gray equivalent, calculated using Monte Carlo radiation transport code MCNPX 2.7.C.Radiat Prot Dosimetry. 2010 Dec;142(2-4):110-9. doi: 10.1093/rpd/ncq264. Epub 2010 Oct 29. Radiat Prot Dosimetry. 2010. PMID: 21036809
-
Photons fluence to local skin Dose coefficients and benchmark with three Monte-Carlo codes. Application to the computation of radioactive material transport limits.Appl Radiat Isot. 2021 Oct;176:109892. doi: 10.1016/j.apradiso.2021.109892. Epub 2021 Aug 14. Appl Radiat Isot. 2021. PMID: 34418729 Review.
-
Development of a secondary standard ionization chamber for environmental level ambient dose equivalent measurement.Appl Radiat Isot. 2022 Feb;180:110038. doi: 10.1016/j.apradiso.2021.110038. Epub 2021 Nov 26. Appl Radiat Isot. 2022. PMID: 34861619 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources