Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Feb;42(2):177-85.
doi: 10.1016/j.joen.2015.10.005. Epub 2015 Nov 26.

Cone-beam Computed Tomography for Detecting Vertical Root Fractures in Endodontically Treated Teeth: A Systematic Review

Affiliations

Cone-beam Computed Tomography for Detecting Vertical Root Fractures in Endodontically Treated Teeth: A Systematic Review

Edwin Chang et al. J Endod. 2016 Feb.

Abstract

Introduction: A vertical root fracture (VRF), commonly found in teeth with endodontic treatment, is challenging to diagnose and has poor treatment outcomes. Cone-beam computed tomography (CBCT) has become an increasingly popular imaging modality in endodontics, but image artifacts arising from root-filling materials may hinder VRF detection. The aim of this investigation was to conduct a systematic review to assess the diagnostic ability of CBCT for detecting VRFs in endodontically treated teeth.

Methods: A systematic review of in vivo clinical diagnostic literature (initial search December 2014, updated August 2015) was conducted. Assessment of methodological quality was performed by using the modified Quality Assessment of Diagnostic Accuracy Studies tool.

Results: Four studies with a total of 130 patients were included. The reported ranges of values were 40%-90% for VRF prevalence, 84% (0.64-0.95) to 100% (0.83-1.00) for sensitivity, 64% (0.35-0.87) to 100% (0.03-1.00) for specificity, 71% (0.51-0.87) to 100% (0.63-1.00) for positive predictive value, and 50% (0.01-0.99) to 100% (0.84-1.00) for negative predictive value. All 4 studies revealed multiple items at high risk or unclear risk of bias.

Conclusions: Because of the significant imprecision in the range of reported estimates and the biases observed in the included studies, there is currently insufficient evidence to suggest that CBCT is a reliable test in detecting VRFs in endodontically treated teeth.

Keywords: Cone beam computed tomography; diagnosis; review literature as topic; tooth fractures.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources