Surgeons changing the approach for total hip arthroplasty from posterior to direct anterior with fluoroscopy should consider potential excessive cup anteversion and flexion implantation of the stem in their early experience

Affiliations

Surgeons changing the approach for total hip arthroplasty from posterior to direct anterior with fluoroscopy should consider potential excessive cup anteversion and flexion implantation of the stem in their early experience

Hideo Kobayashi et al. Int Orthop. 2016 Sep.

Abstract

Purpose: Many reports outline the benefits derived from using the direct anterior approach (DAA) in primary total hip arthroplasty (THA); however, the learning curve for the DAA has not been well documented, and the complications associated with the DAA during this learning curve seem relatively high. The aim of this study was to investigate implant positioning in primary THA, when the surgeon was a novice at the DAA, and had previously used the standard posterior approach (PA).

Patients and methods: We investigated implant positioning in the first 80 consecutive THA cases performed by two senior surgeons using the DAA (with fluoroscopic assistance), and compared them to the same two surgeons' previous 80 respective THA cases performed using their previous standard posterior approach.

Results: Cup positioning accuracy was higher for the DAA (p < 0.001) but greater cup anteversion (19.3° ± 11.0 using the PA vs 27.6° ± 6.3 using DAA, p < 0.0001) was also demonstrated. A total of 69.3 % of cups in the DAA group were positioned with an anteversion angle greater than their target angle. In the DAA group the stem was more frequently positioned in flexion and less frequently in neutral than for the PA group.

Conclusions: Although fluoroscopic assistance seemed to decrease complications such as femoral fracture, surgeons changing from PA to DAA for THA should consider potential excessive cup anteversion and flexion implantation of the stem in their early experience with DAA.

Keywords: Direct anterior approach; Fluoroscopy; Implant position; Total hip arthroplasty.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Bone Joint Surg Am. 1978 Mar;60(2):217-20 - PubMed
    1. J Arthroplasty. 1994 Apr;9(2):137-41 - PubMed
    1. J Arthroplasty. 2002 Apr;17(3):282-8 - PubMed
    1. World J Orthop. 2013 Apr 18;4(2):85-9 - PubMed
    1. Arch Orthop Trauma Surg. 2013 Nov;133(11):1595-600 - PubMed

LinkOut - more resources