Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2016 Apr;263(4):802-7.
doi: 10.1097/SLA.0000000000001375.

Identification and Resection of Clipped Node Decreases the False-negative Rate of Sentinel Lymph Node Surgery in Patients Presenting With Node-positive Breast Cancer (T0-T4, N1-N2) Who Receive Neoadjuvant Chemotherapy: Results From ACOSOG Z1071 (Alliance)

Affiliations
Clinical Trial

Identification and Resection of Clipped Node Decreases the False-negative Rate of Sentinel Lymph Node Surgery in Patients Presenting With Node-positive Breast Cancer (T0-T4, N1-N2) Who Receive Neoadjuvant Chemotherapy: Results From ACOSOG Z1071 (Alliance)

Judy C Boughey et al. Ann Surg. 2016 Apr.

Abstract

Background: The American College of Surgeons Oncology Group Z1071 trial reported a false-negative rate (FNR) of 12.6% with sentinel lymph node (SLN) surgery after neoadjuvant chemotherapy in women presenting with node-positive breast cancer. One proposed method to decrease the FNR is clip placement in the positive node at initial diagnosis with confirmation of clipped node resection at surgery.

Methods: Z1071 was a multi-institutional trial wherein women with clinical T0-T4,N1-N2,M0 breast cancer underwent SLN surgery and axillary dissection (ALND) after neoadjuvant chemotherapy. In cases with a clip placed in the node, the clip location at surgery (SLN or ALND) was evaluated.

Results: A clip was placed at initial node biopsy in 203 patients. In the 170 (83.7%) patients with cN1 disease and at least 2 SLNs resected, clip location was confirmed in 141 cases. In 107 (75.9%) patients where the clipped node was within the SLN specimen, the FNR was 6.8% (confidence interval [CI]: 1.9%-16.5%). In 34 (24.1%) cases where the clipped node was in the ALND specimen, the FNR was 19.0% (CI: 5.4%-41.9%). In cases without a clip placed (n = 355) and in those where clipped node location was not confirmed at surgery (n = 29), the FNR was 13.4% and 14.3%, respectively.

Conclusions: Clip placement at diagnosis of node-positive disease with removal of the clipped node during SLN surgery reduces the FNR of SLN surgery after neoadjuvant chemotherapy. Clip placement in the biopsy-proven node at diagnosis and evaluation of resected specimens for the clipped node should be considered when conducting SLN surgery in this setting.

PubMed Disclaimer

References

    1. Bonnema J, van Geel AN, van Ooijen B, et al. Ultrasound-guided aspiration biopsy for detection of nonpalpable axillary node metastases in breast cancer patients: new diagnostic method. World J Surg. 1997;21(3):270–4. - PubMed
    1. Garcia-Ortega MJ, Benito MA, Vahamonde EF, et al. Pretreatment axillary ultrasonography and core biopsy in patients with suspected breast cancer: diagnostic accuracy and impact on management. European journal of radiology. 2011;79(1):64–72. - PubMed
    1. Koelliker SL, Chung MA, Mainiero MB, et al. Axillary lymph nodes: US-guided fine-needle aspiration for initial staging of breast cancer--correlation with primary tumor size. Radiology. 2008;246(1):81–9. - PubMed
    1. Ciatto S, Brancato B, Risso G, et al. Accuracy of fine needle aspiration cytology (FNAC) of axillary lymph nodes as a triage test in breast cancer staging. Breast Cancer Res Treat. 2007;103(1):85–91. - PubMed
    1. Altomare V, Guerriero G, Carino R, et al. Axillary lymph node echo-guided fine-needle aspiration cytology enables breast cancer patients to avoid a sentinel lymph node biopsy. Preliminary experience and a review of the literature. Surgery today. 2007;37(9):735–9. - PubMed

Publication types

MeSH terms

Substances