External Fixator for Maintaining Reduction Before Volar Plating: A Simple Treatment Method for Association of Osteosynthesis Type C3 Distal Radius Fracture
- PMID: 26651103
- DOI: 10.1097/BTH.0000000000000108
External Fixator for Maintaining Reduction Before Volar Plating: A Simple Treatment Method for Association of Osteosynthesis Type C3 Distal Radius Fracture
Abstract
Volar plating for Association of Osteosynthesis type C3 distal radius fractures involves more time and more radiation exposure because it is extremely difficult to simultaneously maintain the reduction and restore the congruity of the articular surface. The authors present a technique of maintaining the acceptable reduction by using an external fixator followed by open volar plating for restoring articular congruity. A consecutive series of 96 Association of Osteosynthesis type C3 distal radius fractures treated with the technique were retrospectively reviewed between January 2004 and December 2012. The technique makes surgery simpler and more effective, and reduces radiation exposure.
Similar articles
-
A randomized comparison of volar plate and external fixation for intra-articular distal radius fractures.J Hand Surg Am. 2015 Jan;40(1):34-41. doi: 10.1016/j.jhsa.2014.09.025. Epub 2014 Oct 29. J Hand Surg Am. 2015. PMID: 25446409 Clinical Trial.
-
Analysis of the complications of palmar plating versus external fixation for fractures of the distal radius.J Hand Surg Am. 2011 Oct;36(10):1614-20. doi: 10.1016/j.jhsa.2011.06.030. Epub 2011 Aug 17. J Hand Surg Am. 2011. PMID: 21849236
-
A novel non-bridging external fixator construct versus volar angular stable plating for the fixation of intra-articular fractures of the distal radius--a biomechanical study.Injury. 2010 Feb;41(2):204-9. doi: 10.1016/j.injury.2009.09.025. Epub 2009 Oct 9. Injury. 2010. PMID: 19818959
-
[Is external or internal distraction useful for treating distal radial fractures?].Hand Surg Rehabil. 2016 Dec;35S:S86-S88. doi: 10.1016/j.hansur.2016.03.014. Epub 2016 Oct 26. Hand Surg Rehabil. 2016. PMID: 27890218 Review. French.
-
Dorsal distraction plating for highly comminuted distal radius fractures.J Hand Surg Am. 2015 Feb;40(2):355-7. doi: 10.1016/j.jhsa.2014.10.005. Epub 2014 Nov 15. J Hand Surg Am. 2015. PMID: 25459381 Free PMC article. Review. No abstract available.