Roentgenographic measurement of pedicle screw penetration
- PMID: 2665995
Roentgenographic measurement of pedicle screw penetration
Abstract
Potential complications due to pedicle screw penetration of the anterior cortex include injury to vascular, visceral, ureteral, sympathetic, and neural structures. This study examined the accuracy of lateral roentgenographic techniques in determining actual screw penetration in vertebral levels T12 through S1 of ten unilateral sets of pedicles in five anatomic specimens. A true lateral roentgenogram alone was inaccurate for determining the penetration of the anterior cortex by a pedicle screw. The greatest discrepancy between roentgenographically apparent and actual screw penetration was found at the L4 and L5 levels. Deviation from a true lateral roentgenographic axis resulted in the most pronounced change in roentgenographically apparent screw penetration at L4 and L5. The roentgenographic axes resulting in the closest approximation of actual screw penetrations were 5 degrees and 10 degrees above the true lateral axis for the T12-L3 and the L4-S1 levels, respectively. At 50% apparent penetration, the screw may be safely assumed to not be penetrating the anterior cortex using a true lateral roentgenogram. At 80% apparent penetration, 30% and 10% probabilities of actual screw penetration of the anterior cortex exist at L4 and L5, respectively. At 100% apparent penetration, there is an almost 100% probability that the screw is actually protruding through the anterior cortex.
Similar articles
-
Identification of the anterior and posterior portions of the lateral pedicle cortex by roentgenograms in pedicle screw fixation.Surg Radiol Anat. 2002 Dec;24(5):313-8. doi: 10.1007/s00276-002-0049-y. Epub 2002 Oct 30. Surg Radiol Anat. 2002. PMID: 12497223
-
An anatomical study of the mid-lateral pars relative to the pedicle footprint in the lower lumbar spine.Spine (Phila Pa 1976). 2009 Jun 1;34(13):1355-62. doi: 10.1097/BRS.0b013e3181a4f3a9. Spine (Phila Pa 1976). 2009. PMID: 19478655
-
Biomechanical comparison of iliac screws versus interbody femoral ring allograft on lumbosacral kinematics and sacral screw strain.Spine (Phila Pa 1976). 2010 Mar 15;35(6):E198-205. doi: 10.1097/BRS.0b013e3181c142bf. Spine (Phila Pa 1976). 2010. PMID: 20195199
-
The radiologic anatomy of the lumbar and lumbosacral pedicles.Spine (Phila Pa 1976). 2000 Mar 15;25(6):709-15. doi: 10.1097/00007632-200003150-00010. Spine (Phila Pa 1976). 2000. PMID: 10752103
-
Measurement of Chinese lumbar pedicles: with special reference to transpedicular screw fixation.Zhonghua Yi Xue Za Zhi (Taipei). 1994 Jun;53(6):351-6. Zhonghua Yi Xue Za Zhi (Taipei). 1994. PMID: 8087710
Cited by
-
The evolution of image-guided lumbosacral spine surgery.Ann Transl Med. 2015 Apr;3(5):69. doi: 10.3978/j.issn.2305-5839.2015.02.01. Ann Transl Med. 2015. PMID: 25992368 Free PMC article. Review.
-
Reliability of pedicle screw assessment utilizing plain radiographs versus CT reconstruction.Eur Spine J. 1997;6(6):406-10. doi: 10.1007/BF01834069. Eur Spine J. 1997. PMID: 9455670 Free PMC article.
-
Spinal fusion-hardware construct: Basic concepts and imaging review.World J Radiol. 2012 May 28;4(5):193-207. doi: 10.4329/wjr.v4.i5.193. World J Radiol. 2012. PMID: 22761979 Free PMC article.
-
A CT-based study investigating the relationship between pedicle screw placement and stimulation threshold of compound muscle action potentials measured by intraoperative neurophysiological monitoring.Eur Spine J. 2013 Sep;22(9):2062-8. doi: 10.1007/s00586-013-2754-0. Epub 2013 May 19. Eur Spine J. 2013. PMID: 23686531 Free PMC article. Clinical Trial.
-
Observer reliability in evaluating pedicle screw placement using computed tomography.Int Orthop. 2007 Aug;31(4):531-6. doi: 10.1007/s00264-006-0230-8. Epub 2006 Sep 12. Int Orthop. 2007. PMID: 16967277 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources