. 2016 May;20(2):733-8.
doi: 10.1007/s11325-015-1292-x. Epub 2015 Dec 10.

Rates of initial acceptance of PAP masks and outcomes of mask switching

Affiliations

Rates of initial acceptance of PAP masks and outcomes of mask switching

Adel Bachour et al. Sleep Breath. 2016 May.

Abstract

Purpose: Recently, we noticed a considerable development in alleviating problems related to positive airway pressure (PAP) masks. In this study, we report on the initial PAP mask acceptance rates and the effects of mask switching on mask-related symptoms.

Methods: We prospectively collected all cases of mask switching in our sleep unit for a period of 14 months. At the time of the study, we used ResMed™ CPAP devices and masks. Mask switching was defined as replacing a mask used for at least 1 day with another type of mask. Changing to a different size but keeping the same type of mask did not count as mask switching. Switching outcomes were considered failed if the initial problem persisted or reappeared during the year that followed switching.

Results: Our patient pool was 2768. We recorded 343 cases of mask switching among 267 patients. Of the 566 patients who began new PAP therapy, 108 (39 women) had switched masks, yielding an initial mask acceptance rate of 81 %. The reason for switching was poor-fit/uncomfortable mask in 39 %, leak-related in 30 %, outdated model in 25 %, and nasal stuffiness in 6 % of cases; mask switching resolved these problems in 61 %. Mask switching occurred significantly (p = 0.037) more often in women and in new PAP users. The odds ratio for abandoning PAP therapy within 1 year after mask switching was 7.2 times higher (interval 4.7-11.1) than not switching masks.

Conclusion: The initial PAP mask acceptance rate was high. Patients who switched their masks are at greater risk for abandoning PAP therapy.

Keywords: CPAP interface; Mask switching; Outcomes; Side effects; Sleep apnea.