Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2016 Aug;18(8):977-86.
doi: 10.1002/ejhf.458. Epub 2015 Dec 14.

Predicting heart failure decompensation using cardiac implantable electronic devices: a review of practices and challenges

Affiliations
Free article
Review

Predicting heart failure decompensation using cardiac implantable electronic devices: a review of practices and challenges

Nathaniel M Hawkins et al. Eur J Heart Fail. 2016 Aug.
Free article

Abstract

Cardiac implantable electronic devices include remote monitoring tools intended to guide heart failure management. The monitoring focus has been on averting hospitalizations by predicting worsening heart failure. However, although device measurements including intrathoracic impedance correlate with risk of decompensation, they individually predict hospitalizations with limited accuracy. Current 'crisis detection' methods involve repeatedly screening for impending decompensation, and do not adhere to the principles of diagnostic testing. Complex substrate, limited test performance, low outcome incidence, and long test to outcome times inevitably generate low positive and high negative predictive values. When combined with spectrum bias, the generalizability, incremental value, and cost-effectiveness of device algorithms are questionable. To avoid these pitfalls, remote monitoring may need to shift from crisis detection to health maintenance, keeping the patient within an ideal physiological range through continuous 'closed loop' interaction and dynamic therapy adjustment. Test performance must also improve, possibly through combination with physiological sensors in different dimensions, static baseline characteristics, and biomarkers. Complex modelling may tailor monitoring to individual phenotypes, and thus realize a personalized medicine approach. Future randomized controlled trials should carefully consider these issues, and ensure that the interventions tested are generalizable to clinical practice.

Keywords: Cardiac resynchronization therapy; Heart failure; Remote monitoring.

PubMed Disclaimer

Publication types

LinkOut - more resources