Abstract
Exposure of human erythrocytes, under isotonic conditions, to a high voltage pulse of a few kV/cm leads to total hemolysis of the red cells. Experiments described herein demonstrate that the hemolysis is due to the effect of electric field. Neither the effect of current nor the extent of the rapid Joule-heating to the suspending medium shows a direct correlation with the observed hemolysis. Voltage pulsation of the erythrocyte suspension can induce a transmembrane potential across the cell membrane and, at a critical point, it either opens up or creates pores in the red cells. In isotonic saline the pores are small. They allow passage of potassium and sodium ions but not sucrose and hemoglobin molecules. The pores are larger in low ionic conditions and permit permeation of sucrose molecules, but under no circumstances can hemoglobin leak out as the direct result of the voltage pulse. Kinetic measurements indicate that the hemolysis of the red cells follows a stepwise mechanism: leakage of ions leads to an osmotic imbalance which in turn causes a colloidal hemolysis of the red cells. Other effects of the voltage pulsation are also discussed.
Similar articles
-
Electrical hemolysis of human and bovine red blood cells.J Membr Biol. 1976 Dec 28;30(2):135-52. doi: 10.1007/BF01869664. J Membr Biol. 1976. PMID: 13222
-
Voltage-induced pore formation and hemolysis of human erythrocytes.Biochim Biophys Acta. 1977 Dec 1;471(2):227-42. doi: 10.1016/0005-2736(77)90252-8. Biochim Biophys Acta. 1977. PMID: 921980
-
Evidence of voltage-induced channel opening in Na/K ATPase of human erythrocyte membrane.J Membr Biol. 1980 Jul 15;55(2):133-40. doi: 10.1007/BF01871155. J Membr Biol. 1980. PMID: 6251222
-
[Injuries of the erythrocyte membrane and hemolysis--accelerated permeability of cations and macromolecular substances].Nihon Rinsho. 1979 Dec;37(12):3869-74. Nihon Rinsho. 1979. PMID: 395335 Review. Japanese. No abstract available.
-
Red blood cells, phase contrast, interference contrast microscopy and microspectrophotometry.Ups J Med Sci. 1995;100(1):33-40. doi: 10.3109/03009739509178894. Ups J Med Sci. 1995. PMID: 7571162 Review.
Cited by
-
Deformability and stability of erythrocytes in high-frequency electric fields down to subzero temperatures.Biophys J. 1997 Nov;73(5):2653-66. doi: 10.1016/S0006-3495(97)78294-8. Biophys J. 1997. PMID: 9370459 Free PMC article.
-
Relationship of 60-Hz electric-field parameters to the inhibition of growth of Pisum sativum roots.Radiat Environ Biophys. 1981;19(3):227-33. doi: 10.1007/BF01324190. Radiat Environ Biophys. 1981. PMID: 7267989
-
Electric field-induced functional reductions in the K+ channels mainly resulted from supramembrane potential-mediated electroconformational changes.Biophys J. 1998 Jul;75(1):196-206. doi: 10.1016/S0006-3495(98)77506-X. Biophys J. 1998. PMID: 9649379 Free PMC article.
-
Electroporation of cell membranes.Biophys J. 1991 Aug;60(2):297-306. doi: 10.1016/S0006-3495(91)82054-9. Biophys J. 1991. PMID: 1912274 Free PMC article. Review.
-
Electro-mechanical properties of human erythrocyte membranes: the pressure-dependence of potassium permeability.J Membr Biol. 1980 May 23;54(2):103-13. doi: 10.1007/BF01940564. J Membr Biol. 1980. PMID: 7401164