MRI-Based Attenuation Correction for PET/MRI Using Multiphase Level-Set Method
- PMID: 26697962
- DOI: 10.2967/jnumed.115.163550
MRI-Based Attenuation Correction for PET/MRI Using Multiphase Level-Set Method
Abstract
Inaccuracy in MR image-based attenuation correction (MR-AC) leads to errors in quantification and the misinterpretation of lesions in brain PET/MRI studies. To resolve this problem, we proposed an improved ultrashort echo time MR-AC method that was based on a multiphase level-set algorithm with main magnetic field (B0) inhomogeneity correction. We also assessed the feasibility of this level-set-based MR-AC method (MR-AC(level)), compared with CT-AC and MR-AC provided by the manufacturer of the PET/MRI scanner (MR-AC(mMR)).
Methods: Ten healthy volunteers and 20 Parkinson disease patients underwent(18)F-FDG and(18)F-fluorinated-N-3-fluoropropyl-2-β-carboxymethoxy-3-β-(4-iodophenyl)nortropane ((18)F-FP-CIT) PET scans, respectively, using both PET/MRI and PET/CT scanners. The level-set-based segmentation algorithm automatically delimited air, bone, and soft tissue from the ultrashort echo time MR images. For the comparison, MR-AC maps were coregistered to reference CT. PET sinogram data obtained from PET/CT studies were then reconstructed using the CT-AC, MR-AC(mMR), and MR-AC(level) maps. The accuracies of SUV, SUVr (SUV and its ratio to the cerebellum), and specific-to-nonspecific binding ratios obtained using MR-AC(level) and MR-AC(mMR) were compared with CT-AC using region-of-interest- and voxel-based analyses.
Results: There was remarkable improvement in the segmentation of air cavities and bones and the quantitative accuracy of PET measurement using the level set. Although the striatal and cerebellar activities in (18)F-FP-CIT PET and frontal activity in (18)F-FDG PET were significantly underestimated by the MR-AC(mMR), the MR-AC(level) provided PET images almost equivalent to the CT-AC images. PET quantification error was reduced by a factor of 3 using MR-AC(level) (SUV error < 10% in MR-AC(level) and < 30% in MR-AC(mMR) [version VB18P], and < 5% in MR-AC(level) and < 15% in MR-AC(mMR) [VB20P]).
Conclusion: The results of this study indicate that our new multiphase level-set-based MR-AC method improves the quantitative accuracy of brain PET in PET/MRI studies.
Keywords: PET/MRI; attenuation correction; brain PET; level-set segmentation.
© 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Similar articles
-
Segmentation-based MR attenuation correction including bones also affects quantitation in brain studies: an initial result of 18F-FP-CIT PET/MR for patients with parkinsonism.J Nucl Med. 2014 Oct;55(10):1617-22. doi: 10.2967/jnumed.114.138636. Epub 2014 Aug 11. J Nucl Med. 2014. PMID: 25134529
-
Quantitative analysis of MRI-guided attenuation correction techniques in time-of-flight brain PET/MRI.Neuroimage. 2016 Apr 15;130:123-133. doi: 10.1016/j.neuroimage.2016.01.060. Epub 2016 Feb 4. Neuroimage. 2016. PMID: 26853602
-
Comparison of segmentation-based attenuation correction methods for PET/MRI: evaluation of bone and liver standardized uptake value with oncologic PET/CT data.J Nucl Med. 2012 Dec;53(12):1878-82. doi: 10.2967/jnumed.112.104109. Epub 2012 Oct 18. J Nucl Med. 2012. PMID: 23081993
-
Hybrid Positron Emission Tomography/Magnetic Resonance Imaging: Challenges, Methods, and State of the Art of Hardware Component Attenuation Correction.Invest Radiol. 2016 Oct;51(10):624-34. doi: 10.1097/RLI.0000000000000289. Invest Radiol. 2016. PMID: 27175550 Review.
-
Current image acquisition options in PET/MR.Semin Nucl Med. 2015 May;45(3):192-200. doi: 10.1053/j.semnuclmed.2014.12.001. Semin Nucl Med. 2015. PMID: 25841274 Review.
Cited by
-
[11C]-(R)-PK11195 positron emission tomography in patients with complex regional pain syndrome: A pilot study.Medicine (Baltimore). 2017 Jan;96(1):e5735. doi: 10.1097/MD.0000000000005735. Medicine (Baltimore). 2017. PMID: 28072713 Free PMC article.
-
A Multi-view Open-access Dataset of Paired Knee MRI for Motion Artifact Removal.Sci Data. 2025 Jul 9;12(1):1173. doi: 10.1038/s41597-025-05439-1. Sci Data. 2025. PMID: 40634344 Free PMC article.
-
Single STE-MR Acquisition in MR-Based Attenuation Correction of Brain PET Imaging Employing a Fully Automated and Reproducible Level-Set Segmentation Approach.Mol Imaging Biol. 2017 Feb;19(1):143-152. doi: 10.1007/s11307-016-0990-5. Mol Imaging Biol. 2017. PMID: 27459977
-
Generation of PET Attenuation Map for Whole-Body Time-of-Flight 18F-FDG PET/MRI Using a Deep Neural Network Trained with Simultaneously Reconstructed Activity and Attenuation Maps.J Nucl Med. 2019 Aug;60(8):1183-1189. doi: 10.2967/jnumed.118.219493. Epub 2019 Jan 25. J Nucl Med. 2019. PMID: 30683763 Free PMC article.
-
Adaptive template generation for amyloid PET using a deep learning approach.Hum Brain Mapp. 2018 Sep;39(9):3769-3778. doi: 10.1002/hbm.24210. Epub 2018 May 11. Hum Brain Mapp. 2018. PMID: 29752765 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical