Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Sep;26(9):3199-207.
doi: 10.1007/s00330-015-4128-y. Epub 2015 Dec 23.

Quantitative myocardial perfusion with stress dual-energy CT: iodine concentration differences between normal and ischemic or necrotic myocardium. Initial experience

Affiliations

Quantitative myocardial perfusion with stress dual-energy CT: iodine concentration differences between normal and ischemic or necrotic myocardium. Initial experience

Carlos Delgado Sánchez-Gracián et al. Eur Radiol. 2016 Sep.

Abstract

Objectives: To determine whether the quantification of iodine with stress dual-energy computed tomography (DECT-S) allows for the discrimination between a normal and an ischemic or necrotic myocardium using magnetic resonance (MR) as a reference.

Methods: This retrospective study was approved by the institutional review board, with waiver of informed consent. Thirty-six cardiac MR and DECT-S images from patients with suspected coronary artery disease were evaluated. Perfusion defects were visually determined, and myocardial iodine concentration was calculated by two observers using DECT colour-coded iodine maps. Iodine concentration differences were calculated using parametric tests. Receiver operating characteristic (ROC) curve analysis was conducted to estimate the optimal iodine concentration threshold for discriminating pathologic myocardium.

Results: In total, 576 cardiac segments were evaluated. There were differences in mean iodine concentration (p < 0.001) between normal (2.56 ± 0.66 mg/mL), ischemic (1.98 ± 0.36 mg/dL) and infarcted segments (1.35 ± 0.57 mg/mL). A myocardium iodine concentration of 2.1 mg/mL represented the optimal threshold to discriminate between normal and pathologic myocardium (sensitivity 75 %, specificity 73.6 %, area under the curve 0.806). Excellent agreement was found in measured myocardium iodine concentration (intraclass correlation coefficient 0.814).

Conclusion: Cardiac DECT-S with iodine quantification may be useful to differentiate healthy and ischemic or necrotic myocardium.

Key points: • DECT-S allows for determination of myocardial iodine concentration as a quantitative perfusion parameter. • A high interobserver correlation exists in measuring myocardial iodine concentration with DECT-S. • Myocardial iodine concentration may be useful in the assessment of patients with CAD.

Keywords: Iodine maps; Magnetic resonance imaging; Myocardial perfusion imaging; Tomography; X-ray computed.

PubMed Disclaimer

References

    1. Eur Radiol. 2015 Jul;25(7):2115-24 - PubMed
    1. Circulation. 2008 Mar 11;117(10):1283-91 - PubMed
    1. Radiology. 2011 Sep;260(3):689-98 - PubMed
    1. Am J Cardiol. 2009 Mar 15;103(6):812-7 - PubMed
    1. Am J Cardiol. 2009 Aug 1;104(3):318-26 - PubMed