Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2016 Apr;93(4):353-66.
doi: 10.1097/OPX.0000000000000773.

Soft Contact Lenses with Positive Spherical Aberration for Myopia Control

Affiliations
Randomized Controlled Trial

Soft Contact Lenses with Positive Spherical Aberration for Myopia Control

Xu Cheng et al. Optom Vis Sci. 2016 Apr.

Abstract

Purpose: To determine whether soft contact lenses with positive spherical aberration (+SA) can slow myopia progression.

Methods: Eligible subjects (N = 127, primarily Asian) aged 8 to 11 years were randomized to wear either control (spherical design) or test (with +SA) soft daily disposable contact lenses for a minimum of 1 and up to 2 years (treatment phase). Subjects from the initial cohorts (N = 82) were then followed for an additional 1.5 years while wearing a marketed spherical daily disposable contact lens (withdrawal phase). Axial length and spherical equivalent cycloplegic autorefraction (SECAR) were measured at baseline and every 6 months in both phases.

Results: During the first year of treatment, lens type (test vs. control) had a statistically significant impact on axial elongation (p = 0.0409). Eyes wearing test lenses increased in length by 0.11 (65.3%) and 0.14 (38.6%) mm less than eyes wearing control soft lenses at 6 and 12 months, respectively (p < 0.05 at both time points). The principal control of axial elongation occurred during the first 6 months. Spherical equivalent cycloplegic autorefraction change from baseline was significantly less in the test cohort than the control cohort by 0.21D (54.0%) at 6 months (p < 0.05) but not at 12 months (0.14D, p > 0.05). Lens type was not overall a significant factor affecting refractive error change (p = 0.0677). After ceasing treatment, neither the rate of axial elongation nor change in SECAR was significantly different between the initial two cohorts.

Conclusions: The soft contact lens with +SA slowed axial growth of the eye, although this did not translate into a sustained statistically significant effect on SECAR. The majority of the treatment effect occurred in the initial 6 months of wear. No evidence of rebound effect was observed after ceasing treatment.

PubMed Disclaimer

Publication types