Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2016 Nov;18(11):1726-1734.
doi: 10.1093/europace/euv393. Epub 2015 Dec 24.

Incidence of arrhythmias in a large cohort of patients with current implantable cardioverter-defibrillators in Spain: results from the UMBRELLA Registry

Affiliations
Observational Study

Incidence of arrhythmias in a large cohort of patients with current implantable cardioverter-defibrillators in Spain: results from the UMBRELLA Registry

Adolfo Fontenla et al. Europace. 2016 Nov.

Abstract

Aims: The benefit of implantable cardioverter-defibrillators (ICDs) in patients at risk of sudden death has been established in randomized clinical trials (RCTs) using the ICD models available at the time. However, observational large-scale data on the incidence of arrhythmias in up-to-date ICDs implanted according to the current guidelines are scarce. The aim was to assess the incidence of arrhythmias in a large, current ICD population based on a blinded peer review of the detected episodes.

Methods and results: UMBRELLA is a multicentre, observational registry of ICD patients followed by remote monitoring. Stored episodes were classified by a blinded committee of experts. Subgroup analyses were based on clinical profiles established by previous pivotal RCTs of ICDs. Of 1514 enrolled patients, 605 (39.9%) patients had 5951 episodes after 26 ± 17 months follow-up, being 3353 of them (56.3%) sustained ventricular arrhythmias (SVA), and 13.2% of SVA were self-terminated. Appropriate and inappropriate shocks occurred in 11.6 and 5% of patients, respectively. The 3 years cumulative incidence of SVA was 25% (95% CI: 21-28%) in primary prevention patients and 41% (95% CI: 36-47%) in secondary prevention patients (P < 0.001). Male gender, secondary prevention, and atrial fibrillation as basal rhythm were significantly related to a higher incidence of SVA.

Conclusion: This real-world analysis suggests that modern ICD patients have a low rate of appropriate and inappropriate shocks. The risk of SVA in secondary prevention patients is less than what has been reported in RCTs.

Keywords: Appropriate shocks; Implantable cardioverter-defibrillator; Inappropriate shocks; Ventricular arrhythmias.