Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 May 15:79:180-6.
doi: 10.1016/j.bios.2015.12.017. Epub 2015 Dec 11.

Magnetic sensing film based on Fe₃O₄@Au-GSH molecularly imprinted polymers for the electrochemical detection of estradiol

Affiliations

Magnetic sensing film based on Fe₃O₄@Au-GSH molecularly imprinted polymers for the electrochemical detection of estradiol

Qing Han et al. Biosens Bioelectron. .

Abstract

A novel magnetic molecularly imprinted sensing film (MMISF) was fabricated for the determination of estradiol (E2) based on magnetic glassy carbon electrode (MGCE) and magnetic molecularly imprinted polymers (MMIPs). The MMIPs were synthesized by in situ polymerization of glutathione (GSH)-functionalized gold (Au)-coated Fe3O4 (Fe3O4@Au-GSH) nanocomposites and aniline. The MMISF was constructed with MMIPs via a kind of "soft modification" where MMIPs were assembled and immobilized on the surface of MGCE or removed from it by freely installing a magnet into MGCE or not. The E2-MMIPs were obtained by MMIPs recognizing E2 from sample, and the electrochemical detection was carried out after forming the "soft modification" sensing film by putting MGCE into the E2-MMIPs suspension liquid. Afterwards, the "soft modification" MMISF was peeled off from the electrode by removing the magnet from MGCE. The interface of the electrode could be quickly refreshed through simple treatment for the next detection. The structures and morphologies of Fe3O4@Au-GSH, MMIPs and MMISF were investigated by Fourier transform infrared spectrometer, ultraviolet and visible spectrophotometer, scanning electron microscope and atomic force microscope. In addition, the MMISF was successfully used for detecting E2 in milk powder with good sensitivity, selectivity, reproducibility and efficiency. The linear range of the MMISF for E2 was 0.025-10.0μmolL(-1) with the limit of detection of 2.76nmolL(-1) (S/N= 3).

Keywords: Estradiol; Fe(3)O(4)@Au; Magnetic; Molecularly imprinted polymers; Sensing film; Soft modification.

PubMed Disclaimer

Publication types