Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2016 Sep;68(9):1310-9.
doi: 10.1002/acr.22828. Epub 2016 Jul 29.

Utility of Urinary Protein-Creatinine Ratio and Protein Content in a 24-Hour Urine Collection in Systemic Lupus Erythematosus: A Systematic Review and Meta-Analysis

Affiliations
Free article
Meta-Analysis

Utility of Urinary Protein-Creatinine Ratio and Protein Content in a 24-Hour Urine Collection in Systemic Lupus Erythematosus: A Systematic Review and Meta-Analysis

Jorge Medina-Rosas et al. Arthritis Care Res (Hoboken). 2016 Sep.
Free article

Abstract

Objective: To systematically review literature on the utility of spot urinary protein-creatinine ratio (PCR) as a screening test for proteinuria and its ability to accurately measure proteinuria compared with 24-hour urine collection (24H-P) in patients with systemic lupus erythematosus (SLE).

Methods: We conducted a literature search (1900-2015) for articles comparing PCR and 24H-P in SLE patients in the databases Medline, Web of Science, and Embase. Included studies and their results were critically appraised and analyzed.

Results: Thirteen studies (1,001 patients; 84.01% women) were included. Ten studies reported on Pearson's correlation (range 0.67-0.94), and 3 studies reported on Spearman's correlation (range 0.78-1.00). The meta-analysis of studies with Pearson's correlation showed a high overall correlation of 0.80 between 24H-P and PCR, yet with high heterogeneity (I(2) = 97.2%). Correlation analysis is not sufficient to evaluate the utility of a new test against the gold standard test, and analysis on agreement is required. Seven studies reported on agreement: 3 studies analyzed concordance correlation coefficient (0.48-0.94), 3 analyzed intraclass correlation coefficient (0.66-0.95), and 1 analyzed kappa coefficient (0.58). These results confirmed that the agreement between 24H-P and PCR was inappropriate. Three studies included Bland-Altman plots, and the results also demonstrated poor agreement between both tests.

Conclusion: The PCR has a utility as a screening test for proteinuria in SLE patients. The studies' results of 24H-P and PCR showed poor agreement between both tests, signifying that PCR should not be a substitute for the gold standard test (24H-P) to accurately measure proteinuria.

PubMed Disclaimer

LinkOut - more resources