Combination of two-dimensional shear wave elastography with ultrasound breast imaging reporting and data system in the diagnosis of breast lesions: a new method to increase the diagnostic performance
- PMID: 26714967
- DOI: 10.1007/s00330-015-4163-8
Combination of two-dimensional shear wave elastography with ultrasound breast imaging reporting and data system in the diagnosis of breast lesions: a new method to increase the diagnostic performance
Abstract
Objectives: To evaluate the diagnostic performance of a new method of combined two-dimensional shear wave elastography (i.e. virtual touch imaging quantification, VTIQ) and ultrasound (US) Breast Imaging Reporting and Data System (BI-RADS) in the differential diagnosis of breast lesions.
Materials and methods: From September 2014 to December 2014, 276 patients with 296 pathologically proven breast lesions were enrolled in this study. The conventional US images were interpreted by two independent readers. The diagnosis performances of BI-RADS and combined BI-RADS and VTIQ were evaluated, including the area under the receiver operating characteristic curve (AUROC), sensitivity and specificity. Observer consistency was also evaluated.
Results: Pathologically, 212 breast lesions were benign and 84 were malignant. Compared with BI-RADS alone, the AUROCs and specificities of the combined method for both readers increased significantly (AUROC: 0.862 vs. 0.693 in reader 1, 0.861 vs. 0.730 in reader 2; specificity: 91.5 % vs. 38.7 % in reader 1, 94.8 % vs. 47.2 % in reader 2; all P < .05). The Kappa value between the two readers for BI-RADS assessment was 0.614, and 0.796 for the combined method.
Conclusion: The combined VTIQ and BI-RADS had a better diagnostic performance in the diagnosis of breast lesions in comparison with BI-RADS alone.
Key points: • Combination of conventional ultrasound and elastography distinguishes breast cancers more effectively. • Combination of conventional ultrasound and elastography increases observer consistency. • BI-RADS weights more than the 2D-SWE with an increase in malignancy probability.
Keywords: Breast; Breast Imaging Reporting and Data System (BI-RADS); Cancer; Two-dimensional shear wave elastography; Ultrasound.
Similar articles
-
Value of Virtual Touch Tissue Imaging Quantification for Evaluation of Ultrasound Breast Imaging-Reporting and Data System Category 4 Lesions.Ultrasound Med Biol. 2016 Sep;42(9):2050-7. doi: 10.1016/j.ultrasmedbio.2016.04.002. Epub 2016 May 9. Ultrasound Med Biol. 2016. PMID: 27174418
-
Combination of different types of elastography in downgrading ultrasound Breast Imaging-Reporting and Data System category 4a breast lesions.Breast Cancer Res Treat. 2019 Apr;174(2):423-432. doi: 10.1007/s10549-018-05072-0. Epub 2018 Dec 4. Breast Cancer Res Treat. 2019. PMID: 30515679
-
A set of shear wave elastography quantitative parameters combined with ultrasound BI-RADS to assess benign and malignant breast lesions.Ultrasound Med Biol. 2015 Apr;41(4):960-6. doi: 10.1016/j.ultrasmedbio.2014.11.014. Epub 2015 Feb 17. Ultrasound Med Biol. 2015. PMID: 25701532
-
Diagnostic Accuracy of Shear-Wave Elastography for Breast Lesion Characterization in Women: A Systematic Review and Meta-Analysis.J Am Coll Radiol. 2022 May;19(5):625-634.e0. doi: 10.1016/j.jacr.2022.02.022. Epub 2022 Mar 28. J Am Coll Radiol. 2022. PMID: 35358483
-
Value of sonoelastography for diagnosis of breast non-mass lesions and comparison with BI-RADS: A systematic review and meta-analysis.Medicine (Baltimore). 2024 Jun 7;103(23):e38425. doi: 10.1097/MD.0000000000038425. Medicine (Baltimore). 2024. PMID: 38847732 Free PMC article.
Cited by
-
Virtual Touch IQ elastography reduces unnecessary breast biopsies by applying quantitative "rule-in" and "rule-out" threshold values.Sci Rep. 2018 Feb 26;8(1):3583. doi: 10.1038/s41598-018-22065-7. Sci Rep. 2018. PMID: 29483627 Free PMC article.
-
Non-mass Breast Lesions: Could Multimodal Ultrasound Imaging Be Helpful for Their Diagnosis?Diagnostics (Basel). 2022 Nov 23;12(12):2923. doi: 10.3390/diagnostics12122923. Diagnostics (Basel). 2022. PMID: 36552930 Free PMC article.
-
Can strain elastography combined with ultrasound breast imaging reporting and data system be a more effective method in the differentiation of benign and malignant breast lesions?J Med Ultrason (2001). 2017 Oct;44(4):289-296. doi: 10.1007/s10396-017-0772-y. Epub 2017 Feb 2. J Med Ultrason (2001). 2017. PMID: 28154989
-
Quality Measurement of Two-dimensional Shear Wave Speed Imaging for Breast Lesions: the Associated Factors and the Impact to Diagnostic Performance.Sci Rep. 2017 Jul 11;7(1):5076. doi: 10.1038/s41598-017-05281-5. Sci Rep. 2017. PMID: 28698632 Free PMC article.
-
The Japanese breast cancer society clinical practice guidelines for breast cancer screening and diagnosis, 2022 edition.Breast Cancer. 2024 Mar;31(2):157-164. doi: 10.1007/s12282-023-01521-x. Epub 2023 Nov 16. Breast Cancer. 2024. PMID: 37973686 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources
Medical