[Does the renal threshold change? Insulin therapy, based on urine glucose concentration, controlled by a dosage-measuring computer]
- PMID: 2671856
[Does the renal threshold change? Insulin therapy, based on urine glucose concentration, controlled by a dosage-measuring computer]
Abstract
The insulin treatment of 8 diabetic patients was controlled by a microprocessor in order to compare dosage adjustment based on blood glucose and urine glucose determination. In the first month of the treatment the modifications in the insulin doses were suggested by the devices accordingly to blood glucose values, determined by the patients at home four times daily. Then the treatment was guided by the first voided urine glucose concentrations for three months. The treatment based on urine glucose concentration insured the good metabolic control previously achieved by blood glucose values on the basis of blood glucose profile and glycohaemoglobin values. There was no difference between the two treatments in the occurrence of hypoglycemia. The average of the patients renal threshold measured by the authors' method came close to the normal value and proved to be almost constantly related to every single patient. The results support glucosuria-based dosage adjustment as a supplementary for glucose control.
Similar articles
-
Urine glucose testing: reliable backup for whole blood glucose monitoring.J Fam Pract. 1992 Apr;34(4):495-7. J Fam Pract. 1992. PMID: 1556542
-
Glycaemic control with modified intensive insulin injections (MII) using insulin pens and premixed insulin in children with type-1 diabetes: a randomized controlled trial.J Trop Pediatr. 2006 Aug;52(4):276-81. doi: 10.1093/tropej/fmk005. Epub 2006 Jan 12. J Trop Pediatr. 2006. PMID: 16410276 Clinical Trial.
-
Management of diabetics with the use of a microprocessor: comparison of insulin treatments based on blood and urine glucose levels.Acta Diabetol Lat. 1988 Jan-Mar;25(1):33-40. doi: 10.1007/BF02581243. Acta Diabetol Lat. 1988. PMID: 3043988
-
[Improvement in the treatment of diabetes by means of a portable insulin-infusion apparatus. Preliminary results in 4 unstable juvenile diabetics].Schweiz Med Wochenschr. 1980 Nov 22;110(47):1761-3. Schweiz Med Wochenschr. 1980. PMID: 7006076 German.
-
Is the frequency of self-monitoring of blood glucose related to long-term metabolic control? Multicenter analysis including 24,500 patients from 191 centers in Germany and Austria.Exp Clin Endocrinol Diabetes. 2006 Jul;114(7):384-8. doi: 10.1055/s-2006-924152. Exp Clin Endocrinol Diabetes. 2006. PMID: 16915542
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical