Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2015 Dec;56(13):8207-14.
doi: 10.1167/iovs.15-17822.

Concordance of Macular Pigment Measurement Using Customized Heterochromatic Flicker Photometry and Fundus Autofluorescence in Age-Related Macular Degeneration

Affiliations
Randomized Controlled Trial

Concordance of Macular Pigment Measurement Using Customized Heterochromatic Flicker Photometry and Fundus Autofluorescence in Age-Related Macular Degeneration

Kwadwo Owusu Akuffo et al. Invest Ophthalmol Vis Sci. 2015 Dec.

Abstract

Purpose: We compared macular pigment (MP) measurements using customized heterochromatic flicker photometry (Macular Metrics Densitometer) and dual-wavelength fundus autofluorescence (Heidelberg Spectralis HRA + OCT MultiColor) in subjects with early age-related macular degeneration (AMD).

Methods: Macular pigment was measured in 117 subjects with early AMD (age, 44-88 years) using the Densitometer and Spectralis, as part of the Central Retinal Enrichment Supplementation Trial (CREST; ISRCTN13894787). Baseline and 6-month study visits data were used for the analyses. Agreement was investigated at four different retinal eccentricities, graphically and using indices of agreement, including Pearson correlation coefficient (precision), accuracy coefficient, and concordance correlation coefficient (ccc).

Results: Agreement was poor between the Densitometer and Spectralis at all eccentricities, at baseline (e.g., at 0.25° eccentricity, accuracy = 0.63, precision = 0.35, ccc = 0.22) and at 6 months (e.g., at 0.25° eccentricity, accuracy = 0.52, precision = 0.43, ccc = 0.22). Agreement between the two devices was significantly greater for males at 0.5° and 1.0° of eccentricity. At all eccentricities, agreement was unaffected by cataract grade.

Conclusions: In subjects with early AMD, MP measurements obtained using the Densitometer and Spectralis are not statistically comparable and should not be used interchangeably in either the clinical or research setting. Despite this lack of agreement, statistically significant increases in MP, following 6 months of supplementation with macular carotenoids, were detected with each device, confirming that these devices are capable of measuring change in MP within subjects over time. (http://www.controlled-trials.com number, ISRCTN13894787.).

PubMed Disclaimer

Publication types

Substances

Associated data

LinkOut - more resources