Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Feb;136(2):265-70.
doi: 10.1007/s00402-015-2399-z. Epub 2016 Jan 7.

Early clinical and radiological results of total knee arthroplasty using patient-specific guides in obese patients

Affiliations

Early clinical and radiological results of total knee arthroplasty using patient-specific guides in obese patients

Rahij Anwar et al. Arch Orthop Trauma Surg. 2016 Feb.

Abstract

Purpose: Total knee arthroplasty (TKA) is a challenging procedure in patients with a high body mass index (BMI). The aim of our study was to assess the outcome and accuracy of restoration of mechanical alignment in TKA using patient-specific guides (PSG) involving patients with high BMI.

Materials and methods: Patients with BMI of 30 or above were enrolled in the study. The mean age of the patients was 65.15 years. The study comprised of 46 males and 54 females. Total knee arthroplasty was planned after a pre-operative MRI and long leg x-ray films using customized PSG.

Results: Of the 105 knees (100 patients) in the study, average BMI was 35.42 kg/m(2) (30-56). Twenty patients (20 %) had class III obesity (≥40 kg/m(2)). The average blood loss and operative time were 236.1 ml (range 50-700 ml) and 92.2 min (65-130 min), respectively. The average post-operative mechanical axis was noted to be 1.85° varus (range 4° valgus to 6° varus). Eighty-eight patients (86.27 %) had mechanical alignment within 3° of neutral. There were no adverse intraoperative events. One patient had deep infection that required a two-stage revision. The average post-operative range of motion at 1-year follow-up was 105.8° (range 80°-130°).

Conclusion: Patient-specific guides technology restores the coronal mechanical axis reliably in obese patients without adversely affecting outcomes. Our short-term follow-up has shown favorable outcomes. Surgeons should use these customized jigs as a guide and adjust the size of components, alignment and rotation according to normal surgical principles.