Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Apr;27(4):463-8.
doi: 10.1111/jce.12914. Epub 2016 Feb 12.

Bileaflet Mitral Valve Prolapse and Risk of Ventricular Dysrhythmias and Death

Affiliations

Bileaflet Mitral Valve Prolapse and Risk of Ventricular Dysrhythmias and Death

Benjamin D Nordhues et al. J Cardiovasc Electrophysiol. 2016 Apr.

Abstract

Introduction: Bileaflet mitral valve prolapse (BiMVP) is common among survivors of otherwise unexplained sudden cardiac death, but prognostic implications of BiMVP are unknown. This study evaluated whether patients with BiMVP are at higher risk for ventricular dysrhythmias, ICD placement, or death compared to controls with either single-leaflet mitral valve prolapse (SiMVP) or no mitral valve prolapse (MVP).

Methods and results: This retrospective, matched cohort study included 18,786 patients who underwent echocardiography at Mayo Clinic between June 1990 and September 2014. The study included three cohorts: BiMVP, SiMVP, and controls without MVP. We assessed rates of ventricular dysrhythmias, ICD placement, and all-cause mortality between groups. BiMVP was associated with higher rates of ventricular tachycardia compared to SiMVP and controls (adjusted HR 1.48 [1.14-1.92], P = 0.003 and 1.40 [1.04-1.88], P = 0.026, respectively); however, there were no statistically significant differences in rates of ventricular fibrillation/cardiac arrest or ICD placement between groups. BiMVP was associated with a lower rate of all-cause mortality compared to SiMVP and controls (adjusted HR 0.86 [0.79-0.94], P = 0.0008, and 0.55 [0.50-0.60], P < 0.0001, respectively).

Conclusion: Although BiMVP is associated with ventricular tachycardia, it is not associated with an increased risk of cardiac arrest/ventricular fibrillation or ICD implantation and is, paradoxically, associated with a better survival compared to SiMVP or matched controls. The findings suggest that, despite its association with ventricular tachycardia, BiMVP in the absence of other risk factors does not seem to portend a poor prognosis at the population level.

Keywords: bileaflet mitral valve prolapse; implantable cardioverter-defibrillator; mitral valve prolapse; sudden cardiac death; ventricular fibrillation; ventricular tachycardia.

PubMed Disclaimer

Comment in

Similar articles

Cited by

MeSH terms

LinkOut - more resources