Heidelberg Edge Perimeter: The New Method of Perimetry
- PMID: 26771985
- DOI: 10.17219/acem/43834
Heidelberg Edge Perimeter: The New Method of Perimetry
Abstract
Glaucoma is an optic nerve neuropathy associated with progressive visual field loss. One of the most frequent eye diseases these days, it is believed to have affected 60 million people worldwide in 2014. Various visual field examination methods are known, from the confrontational test to kinetic and static perimetry. The latest device to access the visual field is the Heidelberg Edge Perimeter (HEP). It is a flicker perimeter, but, unlike others of its kind, it uses a unique stimulus called FDF (Flicker Defined Form). A 5-grade round stimulus is created by reversing the phase of flickering black and white dots, thereby forming illusory outlines. The test uses randomly flickering points in medium illumination (50 cd/m²). The background remains the same during the whole test. Background luminance is 50 cd/m2, the marker showing time is 400 ms, and the frequency is 15 Hz. Current studies show that HEP can detect early visual field loss which remains invisible during a standard visual field test with standard automated perimetry. HEP might also prove useful in the early detection of other diseases connected with visual field loss, for example in neurology.
Similar articles
-
[First experience with the Heidelberg Edge Perimeter® on patients with ocular hypertension and preperimetric glaucoma].Klin Monbl Augenheilkd. 2012 Apr;229(4):319-22. doi: 10.1055/s-0031-1299210. Epub 2012 Apr 11. Klin Monbl Augenheilkd. 2012. PMID: 22495996 German.
-
Heidelberg edge perimeter employment in glaucoma diagnosis--preliminary report.Adv Clin Exp Med. 2012 Sep-Oct;21(5):665-70. Adv Clin Exp Med. 2012. PMID: 23356204 Review.
-
Flicker defined form perimetry in glaucoma suspects with normal achromatic visual fields.Curr Eye Res. 2015 Jul;40(7):683-9. doi: 10.3109/02713683.2014.957324. Epub 2014 Sep 10. Curr Eye Res. 2015. PMID: 25207744
-
Comparison of Visual Field Measurement with Heidelberg Edge Perimeter and Humphrey Visual Field Analyzer in Patients with Ocular Hypertension.Adv Clin Exp Med. 2016 Sep-Oct;25(5):937-944. doi: 10.17219/acem/62142. Adv Clin Exp Med. 2016. PMID: 28028959
-
A review of current technology used in evaluating visual function in glaucoma.Semin Ophthalmol. 2010 Sep-Nov;25(5-6):309-16. doi: 10.3109/08820538.2010.518898. Semin Ophthalmol. 2010. PMID: 21091017 Review.
Cited by
-
Simplified automatic method for measuring the visual field using the perimeter ZERK 1.Biomed Eng Online. 2016 Jul 25;15(1):88. doi: 10.1186/s12938-016-0210-1. Biomed Eng Online. 2016. PMID: 27456974 Free PMC article.
-
Visual Perception in Expert Athletes: The Case of Rock Climbers.Front Psychol. 2022 Jul 14;13:903518. doi: 10.3389/fpsyg.2022.903518. eCollection 2022. Front Psychol. 2022. PMID: 35911052 Free PMC article.
-
Flicker defined form and RareBit measurements lack in specificity of visual pathways.Int J Ophthalmol. 2020 Mar 18;13(3):417-424. doi: 10.18240/ijo.2020.03.08. eCollection 2020. Int J Ophthalmol. 2020. PMID: 32309178 Free PMC article.
-
Validation and reproducibility of the Heidelberg Edge Perimeter in the detection of glaucomatous visual field defects.Int J Ophthalmol. 2019 Apr 18;12(4):577-581. doi: 10.18240/ijo.2019.04.08. eCollection 2019. Int J Ophthalmol. 2019. PMID: 31024809 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical