Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016;80(3):689-95.
doi: 10.1253/circj.CJ-15-1077. Epub 2016 Jan 18.

Clinical Feasibility of Simultaneous Acquisition Rest (99m)Tc/Stress (201)Tl Dual-Isotope Myocardial Perfusion Single-Photon Emission Computed Tomography With Semiconductor Camera

Affiliations

Clinical Feasibility of Simultaneous Acquisition Rest (99m)Tc/Stress (201)Tl Dual-Isotope Myocardial Perfusion Single-Photon Emission Computed Tomography With Semiconductor Camera

Ayano Makita et al. Circ J. 2016.

Abstract

Background: The aim of this study was to evaluate the clinical feasibility of simultaneous acquisition of rest (99m)Tc-tetrofosmin/stress (201)Tl dual-isotope single-photon emission computed tomography with a semiconductor gamma camera.

Methods and results: Ninety-four patients with known or suspected coronary artery disease (CAD) were enrolled in the study. First, patients were injected with (99m)Tc-tetrofosmin (296 MBq) for rest imaging, followed by (201)Tl (74 MBq) injection during 6 min of vasodilator stress test. Immediately after the stress test, the patients underwent the first electrocardiogram (ECG)-gated simultaneous acquisition including rest and stress perfusion scans. Patients were brought back for the second simultaneous acquisition for the comparison of ECG-gated wall motion between stress and rest scan 30 min later. Coronary angiography was performed in all the patients within 3 months of this protocol. Sensitivity, specificity and accuracy on a per patient basis to detect significant coronary artery stenosis (≥75%) were 88.6%, 79.2% and 86.2%, respectively. Per coronary vessel, sensitivity, specificity and accuracy were as follows: 84.9%, 80.5% and 83% in the left anterior descending coronary artery; 75%, 93.1% and 86.2% in the left circumflex coronary artery; and 74.2%, 85.7% and 81.9% in the right coronary artery.

Conclusions: Simultaneous acquisition of rest (99m)Tc-tetrofosmin/stress (201)Tl dual-isotope protocol had high diagnostic accuracy for significant CAD. (Circ J 2016; 80: 689-695).

PubMed Disclaimer

MeSH terms

Substances

LinkOut - more resources