Assessment of 123I-mIBG and 99mTc-tetrofosmin single-photon emission computed tomographic images for the prediction of arrhythmic events in patients with ischemic heart failure: Intermediate severity innervation defects are associated with higher arrhythmic risk
- PMID: 26791866
- DOI: 10.1007/s12350-015-0336-8
Assessment of 123I-mIBG and 99mTc-tetrofosmin single-photon emission computed tomographic images for the prediction of arrhythmic events in patients with ischemic heart failure: Intermediate severity innervation defects are associated with higher arrhythmic risk
Abstract
Rationale: 123I-mIBG planar image heart-to-mediastinum ratios effectively risk-stratify heart failure (HF) patients. The value of single-photon emission computed tomographic (SPECT) imaging for identifying increased risk of ventricular arrhythmias is less clear. This study sought to determine if findings from simultaneous interpretation of 123I-mIBG and 99mTc-tetrofosmin SPECT are predictive of arrhythmic events (ArEs).
Methods: 123I-mIBG SPECT images from 622 patients with ischemic HF were presented in standard displays alongside 99mTc-tetrofosmin images. Consensus interpretations using a 17-segment model produced summed scores. Cox proportional hazards analyses related findings to adjudicated ArEs over 2 years.
Results: 471 patients had images adequate for total 17-segment scoring. There were 48 ArEs (10.2%). Neither 123I-mIBG nor 99mTc-tetrofosmin SPECT summed scores were univariate predictors. On multivariate proportional hazards analysis, the 123I-mIBG SPECT score was independently predictive of ArEs (HR: 0.975, 95% CI 0.951-0.999, P = 0.042), but HR<1 indicated that risk decreased with increasing score. This occurred because patients with intermediately abnormal SPECT studies had a higher likelihood of ArEs compared to patients with extensive abnormalities.
Conclusions: The presumption of a monotonic increase in ArE risk with increasing summed 123I-mIBG SPECT score may not be correct as ischemic HF patients with abnormalities of intermediate extent appear at highest risk.
Keywords: 123I-mIBG; SPECT; arrhythmias; heart failure.
Comment in
-
Ventricular arrhythmias and autonomic nervous system: evolving role of radionuclide imaging.J Nucl Cardiol. 2017 Apr;24(2):392-394. doi: 10.1007/s12350-016-0411-9. Epub 2016 Jan 27. J Nucl Cardiol. 2017. PMID: 26818144 No abstract available.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous