Use and misuse of metered-dose inhalers by patients with chronic lung disease. A controlled, randomized trial of two instruction methods
- PMID: 2679269
- DOI: 10.1164/ajrccm/140.4.910
Use and misuse of metered-dose inhalers by patients with chronic lung disease. A controlled, randomized trial of two instruction methods
Abstract
Metered-dose inhalers are often used incorrectly by patients with chronic airflow obstruction, and there is a lack of controlled studies designed to evaluate methods to teach the correct use of these devices. Therefore, we screened 100 consecutive stable outpatients for correct or incorrect inhaler use and then conducted a randomized trial of two methods to teach correct use. Patients were classified as correct or incorrect users with a modified metered-dose inhaler containing a thermistor that detected inspiration, inhaler activation, and the duration of breath-holding. Patients were classified as incorrect users if they failed to: (1) activate the inhaler once during inspiration, and/or (2) hold their breath at the end of inspiration. There were 38 correct users and 62 incorrect users. Incorrect users were randomized to one of two teaching protocols: (1) standardized verbal instruction alone, or (2) standardized verbal instruction plus an automatic visual signal during inspiration. Incorrect users were restudied 6 to 10 wk later to reassess technique. Both treatment protocols were equally effective in converting incorrect user. However, the verbal instruction alone required significantly less time than the instruction with the mechanical aid. For all subjects, the proportion using correct technique declined over time, particularly for incorrect users. We also examined a series of patient characteristics, obtained by questionnaire and spirometry, to determine whether they could be used in the clinical setting to identify incorrect users. By discriminant analysis, a group of four variables predicted correct metered-dose inhaler use: bronchodilator responsiveness, a history of additional about proper technique, verbal knowledge of the correct inhaler maneuvers, and the patient's perception of whether it is important to use an inhaler.(ABSTRACT TRUNCATED AT 250 WORDS)
Comment in
-
Use and misuse of metered-dose inhalers by patients with chronic lung disease.Am Rev Respir Dis. 1990 Jun;141(6):1603. doi: 10.1164/ajrccm/141.6.1603. Am Rev Respir Dis. 1990. PMID: 2393428 No abstract available.
Similar articles
-
Characteristics predicting incorrect metered-dose inhaler technique in older subjects.Arch Intern Med. 1996 May 13;156(9):984-8. Arch Intern Med. 1996. PMID: 8624178
-
Assessment of patient acceptance and inhalation technique of a pressurized aerosol inhaler and two breath-actuated devices.Ann Pharmacother. 1993 Jul-Aug;27(7-8):922-7. doi: 10.1177/106002809302700721. Ann Pharmacother. 1993. PMID: 8364279 Clinical Trial.
-
Assessment of the factors affecting the failure to use inhaler devices before and after training.Respir Med. 2015 Apr;109(4):451-8. doi: 10.1016/j.rmed.2015.02.011. Epub 2015 Mar 4. Respir Med. 2015. PMID: 25771037
-
Inhalatory therapy training: a priority challenge for the physician.Acta Biomed. 2007 Dec;78(3):233-45. Acta Biomed. 2007. PMID: 18330086 Review.
-
Inhaler and spacer use in obstructive airway diseases.Am Fam Physician. 1990 Oct;42(4):1007-13. Am Fam Physician. 1990. PMID: 2220509 Review.
Cited by
-
Evaluation of the effectiveness of four different inhalers in patients with chronic obstructive pulmonary disease.Thorax. 1995 Nov;50(11):1183-7. doi: 10.1136/thx.50.11.1183. Thorax. 1995. PMID: 8553275 Free PMC article.
-
Effect of novel inhaler technique reminder labels on the retention of inhaler technique skills in asthma: a single-blind randomized controlled trial.NPJ Prim Care Respir Med. 2017 Feb 9;27(1):9. doi: 10.1038/s41533-017-0011-4. NPJ Prim Care Respir Med. 2017. PMID: 28184045 Free PMC article. Clinical Trial.
-
Today's improvement in asthma treatment: role of MART and Easyhaler.Multidiscip Respir Med. 2020 Aug 5;15(1):649. doi: 10.4081/mrm.2020.649. eCollection 2020 Jan 28. Multidiscip Respir Med. 2020. PMID: 32983452 Free PMC article.
-
Efficient inhaler devices.Br J Gen Pract. 1996 Mar;46(404):199. Br J Gen Pract. 1996. PMID: 8731630 Free PMC article. No abstract available.
-
Device errors in asthma and COPD: systematic literature review and meta-analysis.NPJ Prim Care Respir Med. 2017 Apr 3;27(1):22. doi: 10.1038/s41533-017-0016-z. NPJ Prim Care Respir Med. 2017. PMID: 28373682 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources