Rapid identification of Streptococcus pneumoniae in blood cultures by using the ImmuLex, Slidex and Wellcogen latex agglutination tests and the BinaxNOW antigen test

Affiliations
Comparative Study

Rapid identification of Streptococcus pneumoniae in blood cultures by using the ImmuLex, Slidex and Wellcogen latex agglutination tests and the BinaxNOW antigen test

O Altun et al. Eur J Clin Microbiol Infect Dis. 2016 Apr.

Abstract

Rapid identification of Streptococcus pneumoniae in blood culture (BC) bottles is important for early directed antimicrobial therapy in pneumococcal bacteraemia. We evaluated a new latex agglutination (LA) test on BC bottles, the ImmuLex™ S. pneumoniae Omni (Statens Serum Institut, Denmark), and compared the performance with the Slidex® pneumo-Kit (bioMérieux, France) and the Wellcogen™ S. pneumoniae (Remel, UK) LA tests, as well as the BinaxNOW® S. pneumoniae (Alere, USA) antigen test. The four tests were directly applied on 358 positive BC bottles with Gram-positive cocci in pairs or chains and on 15 negative bottles. Valid test results were recorded in all cases for ImmuLex and BinaxNOW and in 88.5 % (330/373) and 94.1 % (351/373) of cases for Slidex and Wellcogen, respectively. Based on bottles positive for S. pneumoniae by conventional methods, the sensitivity of ImmuLex was 99.6 %, similar to the other tests (range, 99.6-100 %). Based on bottles positive for non-pneumococcal pathogens, the specificity of ImmuLex was 82.6 %, in comparison to 97.6 % for Slidex (p < 0.01) and 85.4 % for Wellcogen (p = ns). The BinaxNOW test had a lower specificity (64.1 %) than any LA test (p < 0.01). On BC bottles positive for α-haemolytic streptococci, ImmuLex was positive in 12/67 (17.9 %) cases, Slidex in 2/59 (3.4 %) cases, Wellcogen in 11/64 (17.2 %) cases and BinaxNOW in 25/67 (37.3 %) cases. In conclusion, the ImmuLex test provides a valid and sensitive technique for the rapid detection of S. pneumoniae in BC bottles, similar to the other compared methods. However, the specificity was sub-optimal, since the test may cross-react with other Gram-positive bacteria.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Clin Infect Dis. 2008 Mar 15;46(6):926-32 - PubMed
    1. Eur J Clin Microbiol. 1987 Feb;6(1):28-34 - PubMed
    1. J Clin Pathol. 1994 Sep;47(9):796-8 - PubMed
    1. J Clin Microbiol. 2013 Mar;51(3):805-9 - PubMed
    1. Infect Immun. 1993 Jul;61(7):3076-7 - PubMed

MeSH terms

LinkOut - more resources