Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2016 Apr;17(4):393-9.
doi: 10.1093/ehjci/jev340. Epub 2016 Jan 22.

Large lipid-rich coronary plaques detected by near-infrared spectroscopy at non-stented sites in the target artery identify patients likely to experience future major adverse cardiovascular events

Affiliations
Observational Study

Large lipid-rich coronary plaques detected by near-infrared spectroscopy at non-stented sites in the target artery identify patients likely to experience future major adverse cardiovascular events

Ryan D Madder et al. Eur Heart J Cardiovasc Imaging. 2016 Apr.

Abstract

Aims: A recent study demonstrated that intracoronary near-infrared spectroscopy (NIRS) findings in non-target vessels are associated with major adverse cardiovascular and cerebrovascular events (MACCE). It is unknown whether NIRS findings at non-stented sites in target vessels are similarly associated with future MACCE. This study evaluated the association between large lipid-rich plaques (LRP) detected by NIRS at non-stented sites in a target artery and subsequent MACCE.

Methods and results: This study evaluated 121 consecutive registry patients undergoing NIRS imaging in a target artery. After excluding stented segments, target arteries were evaluated for a large LRP, defined as a maximum lipid core burden index in 4 mm (maxLCBI4 mm) ≥400. Excluding events in stented segments, Cox regression analysis was performed to evaluate for an association between a maxLCBI4 mm ≥400 and future MACCE, defined as all-cause mortality, non-fatal acute coronary syndrome, and cerebrovascular events. NIRS detected a maxLCBI4 mm ≥400 in a non-stented segment of the target artery in 17.4% of patients. The only baseline clinical variable marginally associated with MACCE was ejection fraction (HR 0.96, 95% CI 0.93-1.00, P = 0.054). A maxLCBI4 mm ≥400 in a non-stented segment at baseline was significantly associated with MACCE during follow-up (HR 10.2, 95% CI 3.4-30.6, P < 0.001).

Conclusion: Detection of large LRP by NIRS at non-stented sites in a target artery was associated with an increased risk of future MACCE. These findings support ongoing prospective studies to further evaluate the ability of NIRS to identify vulnerable patients.

Keywords: lipid-rich plaque; near-infrared spectroscopy; vulnerable patient.

PubMed Disclaimer

Comment in

Publication types