Measurement of oxygen extraction fraction (OEF): An optimized BOLD signal model for use with hypercapnic and hyperoxic calibration
- PMID: 26801605
- DOI: 10.1016/j.neuroimage.2016.01.021
Measurement of oxygen extraction fraction (OEF): An optimized BOLD signal model for use with hypercapnic and hyperoxic calibration
Abstract
Several techniques have been proposed to estimate relative changes in cerebral metabolic rate of oxygen consumption (CMRO2) by exploiting combined BOLD fMRI and cerebral blood flow data in conjunction with hypercapnic or hyperoxic respiratory challenges. More recently, methods based on respiratory challenges that include both hypercapnia and hyperoxia have been developed to assess absolute CMRO2, an important parameter for understanding brain energetics. In this paper, we empirically optimize a previously presented "original calibration model" relating BOLD and blood flow signals specifically for the estimation of oxygen extraction fraction (OEF) and absolute CMRO2. To do so, we have created a set of synthetic BOLD signals using a detailed BOLD signal model to reproduce experiments incorporating hypercapnic and hyperoxic respiratory challenges at 3T. A wide range of physiological conditions was simulated by varying input parameter values (baseline cerebral blood volume (CBV0), baseline cerebral blood flow (CBF0), baseline oxygen extraction fraction (OEF0) and hematocrit (Hct)). From the optimization of the calibration model for estimation of OEF and practical considerations of hypercapnic and hyperoxic respiratory challenges, a new "simplified calibration model" is established which reduces the complexity of the original calibration model by substituting the standard parameters α and β with a single parameter θ. The optimal value of θ is determined (θ=0.06) across a range of experimental respiratory challenges. The simplified calibration model gives estimates of OEF0 and absolute CMRO2 closer to the true values used to simulate the experimental data compared to those estimated using the original model incorporating literature values of α and β. Finally, an error propagation analysis demonstrates the susceptibility of the original and simplified calibration models to measurement errors and potential violations in the underlying assumptions of isometabolism. We conclude that using the simplified calibration model results in a reduced bias in OEF0 estimates across a wide range of potential respiratory challenge experimental designs.
Keywords: Calibrated BOLD; Cerebral metabolic rate of oxygen consumption; Functional MRI; Mathematical modelling; Respiratory tasks.
Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Measurement of OEF and absolute CMRO2: MRI-based methods using interleaved and combined hypercapnia and hyperoxia.Neuroimage. 2013 Dec;83:135-47. doi: 10.1016/j.neuroimage.2013.06.008. Epub 2013 Jun 13. Neuroimage. 2013. PMID: 23769703 Free PMC article. Clinical Trial.
-
Regional Reproducibility of BOLD Calibration Parameter M, OEF and Resting-State CMRO2 Measurements with QUO2 MRI.PLoS One. 2016 Sep 20;11(9):e0163071. doi: 10.1371/journal.pone.0163071. eCollection 2016. PLoS One. 2016. PMID: 27649493 Free PMC article.
-
Cerebral OEF quantification: A comparison study between quantitative susceptibility mapping and dual-gas calibrated BOLD imaging.Magn Reson Med. 2020 Jan;83(1):68-82. doi: 10.1002/mrm.27907. Epub 2019 Aug 2. Magn Reson Med. 2020. PMID: 31373088
-
Cerebral oxygen extraction fraction MRI: Techniques and applications.Magn Reson Med. 2022 Aug;88(2):575-600. doi: 10.1002/mrm.29272. Epub 2022 May 5. Magn Reson Med. 2022. PMID: 35510696 Free PMC article. Review.
-
Blood oxygenation level-dependent (BOLD)-based techniques for the quantification of brain hemodynamic and metabolic properties - theoretical models and experimental approaches.NMR Biomed. 2013 Aug;26(8):963-86. doi: 10.1002/nbm.2839. Epub 2012 Aug 28. NMR Biomed. 2013. PMID: 22927123 Free PMC article. Review.
Cited by
-
Validation and optimization of hypercapnic-calibrated fMRI from oxygen-sensitive two-photon microscopy.Philos Trans R Soc Lond B Biol Sci. 2016 Oct 5;371(1705):20150359. doi: 10.1098/rstb.2015.0359. Philos Trans R Soc Lond B Biol Sci. 2016. PMID: 27574311 Free PMC article.
-
Graded Hypercapnia-Calibrated BOLD: Beyond the Iso-metabolic Hypercapnic Assumption.Front Neurosci. 2017 May 18;11:276. doi: 10.3389/fnins.2017.00276. eCollection 2017. Front Neurosci. 2017. PMID: 28572755 Free PMC article.
-
Post-stimulus fMRI and EEG responses: Evidence for a neuronal origin hypothesised to be inhibitory.Neuroimage. 2017 Aug 15;157:388-399. doi: 10.1016/j.neuroimage.2017.06.020. Epub 2017 Jun 10. Neuroimage. 2017. PMID: 28610902 Free PMC article.
-
Neuroimaging of vascular reserve in patients with cerebrovascular diseases.Neuroimage. 2019 Feb 15;187:192-208. doi: 10.1016/j.neuroimage.2017.10.015. Epub 2017 Oct 12. Neuroimage. 2019. PMID: 29031532 Free PMC article. Review.
-
Hemodynamic and metabolic changes during hypercapnia with normoxia and hyperoxia using pCASL and TRUST MRI in healthy adults.J Cereb Blood Flow Metab. 2022 May;42(5):861-875. doi: 10.1177/0271678X211064572. Epub 2021 Dec 1. J Cereb Blood Flow Metab. 2022. PMID: 34851757 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources