Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 May;36(5):1000-8.
doi: 10.1097/IAE.0000000000000955.

SMARTPHONE-BASED DILATED FUNDUS PHOTOGRAPHY AND NEAR VISUAL ACUITY TESTING AS INEXPENSIVE SCREENING TOOLS TO DETECT REFERRAL WARRANTED DIABETIC EYE DISEASE

Affiliations

SMARTPHONE-BASED DILATED FUNDUS PHOTOGRAPHY AND NEAR VISUAL ACUITY TESTING AS INEXPENSIVE SCREENING TOOLS TO DETECT REFERRAL WARRANTED DIABETIC EYE DISEASE

Brian C Toy et al. Retina. 2016 May.

Abstract

Purpose: To compare clinical assessment of diabetic eye disease by standard dilated examination with data gathered using a smartphone-based store-and-forward teleophthalmology platform.

Methods: 100 eyes of 50 adult patients with diabetes from a health care safety-net ophthalmology clinic. All patients underwent comprehensive ophthalmic examination. Concurrently, a smartphone was used to estimate near visual acuity and capture anterior and dilated posterior segment photographs, which underwent masked, standardized review. Quantitative comparison of clinic and smartphone-based data using descriptive, kappa, Bland-Altman, and receiver operating characteristic analyses was performed.

Results: Smartphone visual acuity was successfully measured in all eyes. Anterior and posterior segment photography was of sufficient quality to grade in 96 and 98 eyes, respectively. There was good correlation between clinical Snellen and smartphone visual acuity measurements (rho = 0.91). Smartphone-acquired fundus photographs demonstrated 91% sensitivity and 99% specificity to detect moderate nonproliferative and worse diabetic retinopathy, with good agreement between clinic and photograph grades (kappa = 0.91 ± 0.1, P < 0.001; AUROC = 0.97, 95% confidence interval, 0.93-1).

Conclusion: The authors report a smartphone-based telemedicine system that demonstrated sensitivity and specificity to detect referral-warranted diabetic eye disease as a proof-of-concept. Additional studies are warranted to evaluate this approach to expanding screening for diabetic retinopathy.

PubMed Disclaimer

Comment in

  • Correspondence.
    Mitra A, Sen A, Prasad S, Malhotra PP. Mitra A, et al. Retina. 2017 Jun;37(6):e75-e76. doi: 10.1097/IAE.0000000000001643. Retina. 2017. PMID: 28541253 No abstract available.

LinkOut - more resources