Optimal size of cuff bladder for indirect measurement of arterial pressure in adults
- PMID: 2681407
- DOI: 10.1097/00004872-198908000-00002
Optimal size of cuff bladder for indirect measurement of arterial pressure in adults
Abstract
This study tested the hypothesis that a sphygmomanometer cuff bladder long enough to encircle the arm in most adults ('obese cuff') would provide a more accurate and precise estimate of intra-arterial pressure than the usual 'standard' cuff bladder. In 53 patients undergoing diagnostic coronary angiography (35 males, 18 females, aged 36-79 years), indirect blood pressure, measured in the left arm with a random-zero sphygmomanometer, was compared with simultaneously measured femoral intra-arterial pressure. Duplicate indirect measurements were made with each of two cuffs containing bladders measuring 39 x 15 cm ('obese') and 23 x 12 cm ('standard'). The obese cuff bladder encircled 80% or more of the arm circumference in all subjects, whereas the standard cuff bladder met this requirement in only 19% of the subjects. For both systolic and diastolic pressure there was marked interindividual variability in the differences between indirect and direct measurements with both cuffs. With the obese cuff there was no systematic error in the diastolic blood pressure measurement. The standard cuff consistently overestimated diastolic pressure by 7.7 +/- 8.3 mmHg (mean +/- s.d.). For both cuffs, the difference between indirect and direct diastolic pressure increased with arm size (P less than 0.05). Both cuffs underestimated systolic blood pressure, the obese cuff by 15.5 +/- 11.7 mmHg and the standard cuff by 7.6 +/- 12.1 mmHg. These systolic blood pressure underestimates were greater at higher blood pressures (P less than 0.01) and with smaller arms (P less than 0.05). Age was not related to measurement error with either cuff.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
Discrepancies between direct and indirect blood pressure measurements using various recommendations for arm cuff selection.Pediatrics. 2002 Nov;110(5):920-3. doi: 10.1542/peds.110.5.920. Pediatrics. 2002. PMID: 12415030
-
Accuracy of auscultatory blood pressure measurement with a long cuff.Br Med J (Clin Res Ed). 1987 Aug 8;295(6594):354-5. doi: 10.1136/bmj.295.6594.354. Br Med J (Clin Res Ed). 1987. PMID: 3115445 Free PMC article. Clinical Trial.
-
Factors affecting the validity of the standard blood pressure cuff.Clin Physiol. 1993 Nov;13(6):611-20. doi: 10.1111/j.1475-097x.1993.tb00476.x. Clin Physiol. 1993. PMID: 8119055
-
Measurement of blood pressure in the obese.Ann Epidemiol. 1991 May;1(4):321-36. doi: 10.1016/1047-2797(91)90043-c. Ann Epidemiol. 1991. PMID: 1669514 Review.
-
Review: a century of confusion; which bladder for accurate blood pressure measurement?J Hum Hypertens. 1996 Sep;10(9):565-72. J Hum Hypertens. 1996. PMID: 8953199 Review.
Cited by
-
Agreement between large and small cuffs in sphygmomanometry: a quantitative assessment.J Clin Monit. 1994 Mar;10(2):127-33. doi: 10.1007/BF02886825. J Clin Monit. 1994. PMID: 8207453
-
Knowledge, attitude, behavior, and practice of interns toward errors in sphygmomanometer and blood pressure measurement.J Clin Hypertens (Greenwich). 2009 Dec;11(12):748-52. doi: 10.1111/j.1751-7176.2009.00204.x. J Clin Hypertens (Greenwich). 2009. PMID: 20021536 Free PMC article. No abstract available.
-
Use of arterial catheters in the management of acute aortic dissection.Air Med J. 2014 Nov-Dec;33(6):326-30. doi: 10.1016/j.amj.2014.06.001. Epub 2014 Nov 5. Air Med J. 2014. PMID: 25441531 Free PMC article.
-
Use of a neonatal blood pressure cuff to monitor blood pressure in the adult finger--comparison with a standard adult arm cuff.J Clin Monit Comput. 1998 May;14(4):233-8. doi: 10.1023/a:1009934032524. J Clin Monit Comput. 1998. PMID: 9754611
-
Evidence based treatment of hypertension. Measurement of blood pressure: an evidence based review.BMJ. 2001 Apr 14;322(7291):908-11. doi: 10.1136/bmj.322.7291.908. BMJ. 2001. PMID: 11302909 Free PMC article. Review. No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous