Comparative Evaluation of Frictional Properties, Load Deflection Rate and Surface Characteristics of Different Coloured TMA Archwires - An Invitro Study
- PMID: 26816988
- PMCID: PMC4717770
- DOI: 10.7860/JCDR/2015/16117.6962
Comparative Evaluation of Frictional Properties, Load Deflection Rate and Surface Characteristics of Different Coloured TMA Archwires - An Invitro Study
Abstract
Introduction: During tooth movement the success of sliding mechanics is dependent upon various factors which include frictional resistance at bracket-archwire interface, surface roughness of archwire materials and elastic properties of archwires. Ion implantation techniques reduce the frictional force and allow better tooth movement clinically.
Aim: The main objective of this study was to evaluate and compare the frictional properties, load deflection rate and surface characteristics of Honey dew and Purple coloured (Ion implanted) TMA wires with uncoated TMA wires.
Materials and methods: Fifteen archwire samples were divided into three groups comprising of five samples in each group namely, Group I - Uncoated TMA wires (Control), Group II - Purple coloured TMA wires and Group III- Honey dew TMA wires. Friction and load deflection rate testing were performed with the Instron Universal testing machine and the surface characteristics of the wires were evaluated before and after sliding using Scanning Electron Microscope.
Results: The mean frictional characteristics and surface roughness for Honey dew TMA wires was lesser than Purple coloured TMA wires which was statistically significant. Both the coloured TMA wires showed low frictional characteristics and less surface roughness than uncoated TMA wires (the control). The mean load deflection rate was low for both coloured ion implanted TMA wires when compared to uncoated TMA wires which was statistically significant.
Conclusion: Coloured ion implanted TMA wires, especially Honey dew TMA wires have low friction, low load deflection rate and improved surface finish. Hence they can be used in frictionless as well as sliding mechanics, where uncoated TMA wires are inefficient.
Keywords: Friction; Ion implantation; Mechanical properties.
Figures
![[Table/Fig-2]:](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3e27/4717770/d5f19c632aef/jcdr-9-ZC26-g001.gif)
![[Table/Fig-9]:](https://cdn.ncbi.nlm.nih.gov/pmc/blobs/3e27/4717770/12d3303d8cda/jcdr-9-ZC26-g002.gif)
Similar articles
-
Evaluation of kinetic friction between regular and colored titanium molybdenum alloy archwires.Indian J Dent Res. 2018 Mar-Apr;29(2):212-216. doi: 10.4103/ijdr.IJDR_817_16. Indian J Dent Res. 2018. PMID: 29652017
-
Comparative Evaluation of Frictional Resistance Between Different Types of Ceramic Brackets and Stainless Steel Brackets With Teflon-Coated Stainless Steel and Stainless Steel Archwires: An In-Vitro Study.Cureus. 2022 Apr 15;14(4):e24161. doi: 10.7759/cureus.24161. eCollection 2022 Apr. Cureus. 2022. PMID: 35586355 Free PMC article.
-
Evaluation and comparison of surface characteristics of commercially available TMA wires using scanning electron microscopy and optical profilometer.Indian J Dent Res. 2019 Jul-Aug;30(4):548-552. doi: 10.4103/ijdr.IJDR_420_18. Indian J Dent Res. 2019. PMID: 31745051
-
A comparative study of the static and kinetic frictional resistance of titanium molybdenum alloy archwires in stainless steel brackets.Eur J Orthod. 2004 Feb;26(1):105-11. doi: 10.1093/ejo/26.1.105. Eur J Orthod. 2004. PMID: 14994890
-
Frictional behavior of one-dimensional materials: an experimental perspective.Nanoscale Adv. 2024 May 9;6(13):3251-3284. doi: 10.1039/d4na00039k. eCollection 2024 Jun 25. Nanoscale Adv. 2024. PMID: 38933866 Free PMC article. Review.
Cited by
-
Effect of oral environment and prescribed fluoride mouthwashes on different types of TMA wires - An in-vivo study.J Orthod Sci. 2019 May 23;8:8. doi: 10.4103/jos.JOS_72_18. eCollection 2019. J Orthod Sci. 2019. PMID: 31161131 Free PMC article.
-
Effect of anodization on friction behavior of β‑titanium orthodontic archwires.J Orofac Orthop. 2023 Jul;84(4):225-234. doi: 10.1007/s00056-021-00347-6. Epub 2021 Sep 17. J Orofac Orthop. 2023. PMID: 34533584 English.
References
-
- Kapila S, Sachdeva R. Mechanical properties and clinical applications of orthodontic wires. Am J Orthod Dentofacial Orthop. 1989;96(2):100–09. - PubMed
-
- Burstone CJ, Goldberg AJ. Beta titanium: a new orthodontic alloy. Am J Orthod. 1980;77(2):121–32. - PubMed
-
- Drake SR, Wayne DM, Powers JM, Asgar K. Mechanical properties of orthodontic wires in tension, bending, and torsion. Am J Orthod. 1982;82(3):206–10. - PubMed
-
- Vijayalakshmi RD, Nagachandran KS, Kummi P, Jayakumar P. A comparative evaluation of metallurgical properties of stainless steel and TMA archwires with timolium and titanium niobium archwires-an invitro study. Indian J Dent Res. 2009;20(4):448–52. - PubMed
-
- Burstone CJ, Farzin-Nia F. Production of low friction and coloured TMA by Ion implantation. JCO. 1995;29(7):453–61. - PubMed
LinkOut - more resources
Full Text Sources