Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2015 Oct:98 Suppl 9:S140-5.

Comparison of Droplet Digital PCR and Real Time PCR Method for HBV DNA Quantification

  • PMID: 26817223
Comparative Study

Comparison of Droplet Digital PCR and Real Time PCR Method for HBV DNA Quantification

Chatchawal Wongjitrat et al. J Med Assoc Thai. 2015 Oct.

Abstract

Background: HBV infection causes a potential serious public health problem. The ability to detect HBV DNA concentration is an important issue that had been continuously improved. When using quantitative polymerase chain reaction (qPCR), several factors are of concern, for example, sources of material, standard curve calibration, and PCR efficiency. Digital PCR (dPCR) is an alternative PCR-based technique for absolute quantification using Poisson's statistics without requiring a standard curve.

Objective: Compare the data set of HBV DNA generated between dPCR and qPCR methods.

Material and methods: Fifty-four samples were quantified by Abbot's real time PCR and with 2-6 log10 HBV DNA were selected for comparison with dPCR.

Results: Of these 54 samples, there were two outlier samples defined as negative by dPCR, whereas 52 samples were positive by both of these assays. The difference between two assays was less than 0.25 log IU/mL in 24/52 samples (46%) of paired samples; less than 0.5 log IU/mL in 46/52 samples (88%) and less than 1 log in 50/52 samples (96%). The correlation coefficient (r) was 0.788 (p-value < 0.0001). Comparison with qPCR method, data generated by dPCR tend to be an overestimation in the sample with the low level ofHBVDNA concentration and underestimated in the sample with high viral load. The variation of DNA by dPCR measurement might be due to the pre-amplification procedure and PCR template.

Conclusion: Measurement of HBV DNA by using dPCR, the results ofthe HBV DNA copy number tended to be deviated by over- or under-estimated when comparison to real time PCR method. In addition, a large quantity of DNA was used when compared to qPCR. However, the optimum processes of this assay have to be further investigated.

PubMed Disclaimer

Similar articles

Cited by

  • Opioid precursor protein isoform is targeted to the cell nuclei in the human brain.
    Kononenko O, Bazov I, Watanabe H, Gerashchenko G, Dyachok O, Verbeek DS, Alkass K, Druid H, Andersson M, Mulder J, Svenningsen ÅF, Rajkowska G, Stockmeier CA, Krishtal O, Yakovleva T, Bakalkin G. Kononenko O, et al. Biochim Biophys Acta Gen Subj. 2017 Feb;1861(2):246-255. doi: 10.1016/j.bbagen.2016.11.002. Epub 2016 Nov 10. Biochim Biophys Acta Gen Subj. 2017. PMID: 27838394 Free PMC article.

Publication types

LinkOut - more resources