Meta-Analysis
. 2016 Feb;18(2):195-204.
doi: 10.1002/ejhf.470. Epub 2016 Jan 27.

Effect of telemonitoring of cardiac implantable electronic devices on healthcare utilization: a meta-analysis of randomized controlled trials in patients with heart failure

Affiliations
Free article
Meta-Analysis

Effect of telemonitoring of cardiac implantable electronic devices on healthcare utilization: a meta-analysis of randomized controlled trials in patients with heart failure

Catherine Klersy et al. Eur J Heart Fail. 2016 Feb.
Free article

Abstract

Aims: Implantable device telemonitoring (DTM) is a diagnostic adjunct to traditional face-to-face hospital visits. Remote device follow-up and earlier diagnoses facilitated by DTM should reduce healthcare utilization. We explored whether DTM reduces healthcare utilization over standard of care (SoC), without compromising patient outcomes.

Methods and results: This systematic review and meta-analysis of 11 randomized controlled trials on DTM in patients with heart failure consisted of 5702 patients, with a median of 117 [interquartile range (IQR) 76-331] patients per study [age 65 years (IQR 63-67)] and follow-up range of 12-36 months. DTM was associated with a reduction in total number of visits [planned, unplanned, and emergency room (ER)] [relative risk (RR) 0.56; 95% confidence interval (CI) 0.43-0.73, P < 0.001]. Rates of cardiac hospitalizations (RR 0.96; 95% CI 0.82-1.12, P = 0.60) and the composite endpoints of ER, unplanned hospital visits, or hospitalizations (RR 0.99; 95% CI 0.68-1.43, P = 0.96) was similar between the DTM and the SoC groups. An increase in the total number of ER or unscheduled visits (RR 1.37; 95% CI 1.11-1.70, P = 0.004) was observed. This effect was consistent and statistically significant for all studies. Total and cardiac mortality were similar between the groups (DTM RR 0.90; 95% CI 0.69-1.16, P = 0.41; and DTM RR 0.93; 95% CI 0.51-1.69, P = 0.80). Monetary costs favoured DTM (10-55% reduction in five studies).

Conclusions: Compared with SoC, DTM is associated with a marked reduction in planned hospital visits. In addition, DTM was associated with lower monetary costs, despite a modest increase in unplanned hospital and ER visits. DTM did not compromise survival.

Keywords: Cardiac implantable electronic devices; Heart failure; Remote monitoring; Telemonitoring.