Effects on mobility training and de-adaptations in subjects with Spinal Cord Injury due to a Wearable Robot: a preliminary report

Affiliations
Clinical Trial

Effects on mobility training and de-adaptations in subjects with Spinal Cord Injury due to a Wearable Robot: a preliminary report

Patrizio Sale et al. BMC Neurol. .

Abstract

Background: Spinal cord injury (SCI) is a severe neurological disorder associated not only with ongoing medical complications but also with a significant loss of mobility and participation. The introduction of robotic technologies to recover lower limb function has been greatly employed in the rehabilitative practice. The aim of this preliminary report were to evaluate the efficacy, the feasibility and the changes in the mobility and in the de-adaptations of a new rehabilitative protocol for EKSO™ a robotic exoskeleton device in subjects with SCI disease with an impairment of lower limbs assessed by gait analysis and clinical outcomes.

Method: This is a pilot single case experimental A-B (pre-post) design study. Three cognitively intact voluntary participants with SCI and gait disorders were admitted. All subjects were submitted to a training program of robot walking sessions for 45 min daily over 20 sessions. The spatiotemporal parameters at the beginning (T0) and at the end of treatment (T1) were recorded. Other clinical assessments (6 min walking test and Timed Up and Go test) were acquired at T0 and T1.

Results: Robot training were feasible and acceptable and all participants completed the training sessions. All subjects showed improvements in gait spatiotemporal indexes (Mean velocity, Cadence, Step length and Step width) and in 6 min Walking Test (T0 versus T1).

Conclusions: Robot training is a feasible form of rehabilitation for people with SCI. Further investigation regarding long term effectiveness of robot training in time is necessary.

Trial registration: ClinicalTrials.gov NCT02065830.

PubMed Disclaimer

References

    1. Sale P, Mazzarella F, Pagliacci MC, Aito S, Agosti M, Franceschini M. Sport, free time and hobbies in people with spinal cord injury. Spinal Cord. 2012;50(6):452–6. doi: 10.1038/sc.2011.161. - DOI - PubMed
    1. Routhier F, Vincent C, Desrosiers J, Nadeau S. Mobility of wheelchair users: a proposed performance assessment framework. Disabil Rehabil. 2003;25(1):19–34. doi: 10.1080/dre.25.1.19.34. - DOI - PubMed
    1. Del-Ama AJ, Gil-Agudo A, Pons JL, Moreno JC. Hybrid gait training with an overground robot for people with incomplete spinal cord injury: a pilot study. Front Hum Neurosci. 2014;8:298. doi: 10.3389/fnhum.2014.00298. - DOI - PMC - PubMed
    1. Sale P, De Pandis MF, Le Pera D, Sova I, Cimolin V, Ancillao A, et al. Robot-assisted walking training for individuals with Parkinson’s disease: a pilot randomized controlled trial. BMC Neurol. 2013;13:50. doi: 10.1186/1471-2377-13-50. - DOI - PMC - PubMed
    1. Mooney LM, Rouse EJ, Herr HM. Autonomous exoskeleton reduces metabolic cost of human walking during load carriage. J Neuroeng Rehabil. 2014;11:80. doi: 10.1186/1743-0003-11-80. - DOI - PMC - PubMed