Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Jan;5(1):18-25.
doi: 10.1302/2046-3758.51.2000473.

The World Hip Trauma Evaluation Study 3: Hemiarthroplasty Evaluation by Multicentre Investigation - WHITE 3: HEMI - An Abridged Protocol

Affiliations

The World Hip Trauma Evaluation Study 3: Hemiarthroplasty Evaluation by Multicentre Investigation - WHITE 3: HEMI - An Abridged Protocol

A L Sims et al. Bone Joint Res. 2016 Jan.

Abstract

Background: Approximately half of all hip fractures are displaced intracapsular fractures. The standard treatment for these fractures is either hemiarthroplasty or total hip arthroplasty. The recent National Institute for Health and Care Excellence (NICE) guidance on hip fracture management recommends the use of 'proven' cemented stem arthroplasty with an Orthopaedic Device Evaluation Panel (ODEP) rating of at least 3B (97% survival at three years). The Thompsons prosthesis is currently lacking an ODEP rating despite over 50 years of clinical use, likely due to the paucity of implant survival data. Nationally, adherence to these guidelines is varied as there is debate as to which prosthesis optimises patient outcomes.

Design: This study design is a multi-centre, multi-surgeon, parallel, two arm, standard-of-care pragmatic randomised controlled trial. It will be embedded within the WHiTE Comprehensive Cohort Study (ISRCTN63982700). The main analysis is a two-way equivalence comparison between Hemi-Thompson and Hemi-Exeter polished taper with Unitrax head. Secondary outcomes will include radiological leg length discrepancy measured as per Bidwai and Willett, mortality, re-operation rate and indication for re-operation, length of index hospital stay and revision at four months. This study will be supplemented by the NHFD (National Hip Fracture Database) dataset.

Discussion: Evidence on the optimum choice of prosthesis for hemiarthroplasty of the hip is lacking. National guidance is currently based on expert opinion rather than empirical evidence. The incidence of hip fracture is likely to continue to increase and providing high quality evidence on the optimumCite this article: A. L. Sims. The World Hip Trauma Evaluation Study 3: Hemiarthroplasty Evaluation by Multicentre Investigation - WHITE 3: HEMI - An Abridged Protocol. Bone Joint Res 2016;5:18-25. doi: 10.1302/2046-3758.51.2000473.

Keywords: exeter; fracture; hemiarthroplasty; hip; neck of femur; polished stem; randomised; thompsons; trial.

PubMed Disclaimer

Conflict of interest statement

ICMJE conflict of interest:None declared.

Similar articles

Cited by

References

    1. Johnell O, Kanis JA. An estimate of the worldwide prevalence, mortality and disability associated with hip fracture. Osteoporos Int 2004;15:897-902. - PubMed
    1. Müller ME, Koch P, Nazarian S, Schatzker J. The Comprehensive Classification of Fractures of Long Bones. Berlin: Springer-Verlag, 1990.
    1. No authors listed. The National Hip Fracture Database National Report 2010 – Extended version http://www.nhfd.co.uk/20/hipfractureR.nsf/0/5223179d21c352d0802577d20041... (date last accessed 19 January 2016).
    1. Khan RJ, MacDowell A, Crossman P, Keene GS. Cemented or uncemented hemiarthroplasty for displaced intracapsular fractures of the hip–a systematic review. Injury 2002;33:13-17. - PubMed
    1. No authors listed. The management of hip fracture in adults. http://www.nice.org.uk (date last accessed 22 December 2015).