Dimensional accuracy of digital dental models from cone-beam computed tomography scans of alginate impressions according to time elapsed after the impressions
- PMID: 26827986
- DOI: 10.1016/j.ajodo.2015.08.014
Dimensional accuracy of digital dental models from cone-beam computed tomography scans of alginate impressions according to time elapsed after the impressions
Abstract
Introduction: Our objective was to investigate the dimensional accuracy of digital dental models obtained from the cone-beam computed tomography (CBCT) scans of alginate impressions according to the time elapsed after the impressions were taken.
Methods: Alginate impressions were obtained of 20 adults using 2 alginate materials: Alginoplast (Heraeus Kulzer, Hanau, Germany) and Cavex (Cavex Holland, Haarlem, The Netherlands). These impressions were stored in wet conditions and scanned by CBCT immediately after impression-taking and after storage times of 12, 24, 36, 48, 60, and 72 hours. After reconstruction of the 3-dimensional digital dental models, the models were measured, and the data were analyzed to determine the dimensional changes according to the time elapsed. The changes within the measurement error were regarded as clinically acceptable in this study.
Results: The measurement errors ranged from 0.27 to 0.29 mm in the digital dental models obtained from CBCT scans of the alginate impressions. All measurements showed decreasing accuracy with greater elapsed time after the impressions were taken. Changes above the measurement error occurred at 24 and 36 hours for Cavex and Alginoplast, respectively.
Conclusions: Digital dental models can be obtained from CBCT scans of alginate impressions without sending them to a remote laboratory. However, the impressions need to be scanned within 24 hours; otherwise, dimensional changes lead to errors that exceed the error of measurement.
Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions.Korean J Orthod. 2016 May;46(3):129-36. doi: 10.4041/kjod.2016.46.3.129. Epub 2016 May 20. Korean J Orthod. 2016. PMID: 27226958 Free PMC article.
-
Analysis of intra-arch and interarch measurements from digital models with 2 impression materials and a modeling process based on cone-beam computed tomography.Am J Orthod Dentofacial Orthop. 2010 Apr;137(4):456.e1-9; discussion 456-7. doi: 10.1016/j.ajodo.2009.09.019. Am J Orthod Dentofacial Orthop. 2010. PMID: 20362900
-
Reproducibility and accuracy of linear measurements on dental models derived from cone-beam computed tomography compared with digital dental casts.Am J Orthod Dentofacial Orthop. 2014 Sep;146(3):328-36. doi: 10.1016/j.ajodo.2014.05.026. Am J Orthod Dentofacial Orthop. 2014. PMID: 25172255
-
Alginate Materials and Dental Impression Technique: A Current State of the Art and Application to Dental Practice.Mar Drugs. 2018 Dec 29;17(1):18. doi: 10.3390/md17010018. Mar Drugs. 2018. PMID: 30597945 Free PMC article. Review.
-
The Digital Clone: Intraoral Scanning, Face Scans and Cone Beam Computed Tomography Integration for Diagnosis and Treatment Planning.Dent Clin North Am. 2021 Jul;65(3):529-553. doi: 10.1016/j.cden.2021.02.011. Epub 2021 May 3. Dent Clin North Am. 2021. PMID: 34051929 Review.
Cited by
-
Three-dimensional comparison of 2 digital models obtained from cone-beam computed tomographic scans of polyvinyl siloxane impressions and plaster models.Imaging Sci Dent. 2019 Dec;49(4):257-263. doi: 10.5624/isd.2019.49.4.257. Epub 2019 Dec 24. Imaging Sci Dent. 2019. PMID: 31915610 Free PMC article.
-
Effect of Storage Period on Dimensional Stability of Alginplus and Hydrogum 5.J Dent (Tehran). 2017 Jan;14(1):31-39. J Dent (Tehran). 2017. PMID: 28828015 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources