. 2016 May;60(4):513-8.
doi: 10.1093/annhyg/mew003. Epub 2016 Jan 31.

Isocyanate Exposure Below Analytical Detection When a Paint Brush and Roller Are Used to Apply Moisture-Cure Polyurethane Paint

Affiliations

Isocyanate Exposure Below Analytical Detection When a Paint Brush and Roller Are Used to Apply Moisture-Cure Polyurethane Paint

Carolyn K Reeb-Whitaker et al. Ann Occup Hyg. 2016 May.

Abstract

Isocyanate exposure is known to be hazardous when polyurethane paints are applied with a spray gun, but less is known of exposure when paint is applied with a paint brush and roller. Concentrations of 1,6-hexamethylene diisocyanate (HDI) monomer and three HDI polymers were assessed when two moisture-cure polyurethane paints containing 31-35% isocyanates were applied with a paint roller and brush. Short-term 15-min samples were taken during paint application in an indoor test environment with no ventilation (n= 12); in an outdoor test environment (n= 11); and in an outdoor in-situ assessment (n= 22). The outdoor in-situ assessment involved the painting of a bus shelter and light poles at a public transit station over two night shifts. All isocyanate samples were below analytical detection. The analytical limits of detection for HDI monomer, HDI biuret, HDI isocyanurate, and HDI uretdione were 0.005, 0.84, 0.87, and 0.88 µg, respectively. The finding that isocyanate concentrations were below detection is attributed to the use of paint roller and brush which minimize paint aerosolization and the paint formulation itself which contained <1% of volatile HDI monomer.

Keywords: LOD; asthma; coating; negative finding; non-detect.

PubMed Disclaimer

Publication types