Roentgen stereophotogrammetry. Review of orthopedic applications
- PMID: 2683567
- DOI: 10.3109/17453678909149328
Roentgen stereophotogrammetry. Review of orthopedic applications
Abstract
Roentgen stereophotogrammetry is based on radiographic examinations of calibration cages and object markers implanted in the skeleton. Accurate measurements of radiographs and computer-assisted calculations can provide a three-dimensional motion analysis. Since its introduction 15 years ago, roentgen stereophotogrammetry has found an increasing number of orthopedic applications, which are reviewed here: growth, prosthetic fixation, joint kinematics and stability, fracture stability, and the healing course of spinal fusion and pelvic and tibial osteotomies.
Similar articles
-
A roentgen stereophotogrammetric system. Construction, calibration and technical accuracy.Acta Radiol Diagn (Stockh). 1983;24(4):343-52. doi: 10.1177/028418518302400412. Acta Radiol Diagn (Stockh). 1983. PMID: 6637575
-
Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system.Acta Orthop Scand Suppl. 1989;232:1-51. Acta Orthop Scand Suppl. 1989. PMID: 2686344 Review.
-
Roentgen stereophotogrammetry for determination of daily longitudinal bone growth in the rabbit.Acta Radiol Diagn (Stockh). 1978;19(1A):97-105. doi: 10.1177/028418517801901a12. Acta Radiol Diagn (Stockh). 1978. PMID: 645428
-
[Computer application in roentgen stereophotogrammetry in orthopedic problem formulation].Methods Inf Med Suppl. 1978;11:564-80. Methods Inf Med Suppl. 1978. PMID: 279780 German. No abstract available.
-
Roentgen stereophotogrammetric analysis.Acta Radiol. 1990 Mar;31(2):113-26. Acta Radiol. 1990. PMID: 2196921 Review.
Cited by
-
Monoblock versus modular polyethylene insert in uncemented total knee arthroplasty.Acta Orthop. 2016 Dec;87(6):607-614. doi: 10.1080/17453674.2016.1233654. Epub 2016 Sep 20. Acta Orthop. 2016. PMID: 27649258 Free PMC article. Clinical Trial.
-
Accuracy of model-based RSA contour reduction in a typical clinical application.Clin Orthop Relat Res. 2008 Aug;466(8):1978-86. doi: 10.1007/s11999-008-0287-3. Epub 2008 May 29. Clin Orthop Relat Res. 2008. PMID: 18509712 Free PMC article. Clinical Trial.
-
Guideline for RSA and CT-RSA implant migration measurements: an update of standardizations and recommendations.Acta Orthop. 2024 May 30;95:256-267. doi: 10.2340/17453674.2024.40709. Acta Orthop. 2024. PMID: 38819193 Free PMC article.
-
[Implant anchorage: In vivo and in vitro analyses : Clusters for implant anchorage and safety].Orthopadie (Heidelb). 2024 Jul;53(7):519-526. doi: 10.1007/s00132-024-04519-1. Epub 2024 Jun 3. Orthopadie (Heidelb). 2024. PMID: 38829401 Review. German.
-
Biomechanical behaviours of the bone-implant interface: a review.J R Soc Interface. 2019 Jul 26;16(156):20190259. doi: 10.1098/rsif.2019.0259. Epub 2019 Jul 31. J R Soc Interface. 2019. PMID: 31362615 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Other Literature Sources
Medical