Comparison of in vivo polyethylene wear particles between mobile- and fixed-bearing TKA in the same patients
- PMID: 26846659
- DOI: 10.1007/s00167-016-4027-z
Comparison of in vivo polyethylene wear particles between mobile- and fixed-bearing TKA in the same patients
Abstract
Purpose: Polyethylene wear particle generation is one of the most important factors that affects the mid- to long-term results of total knee arthroplasties (TKA). Mobile-bearing total knee prostheses were developed to reduce polyethylene wear generation. However, whether mobile-bearing prostheses actually generate fewer polyethylene wear particles than fixed-bearing prostheses remains controversial. The aim of this study was to compare, within individual patients, the in vivo polyethylene wear particles created by a newly introduced mobile-bearing prosthesis in one knee and a conventional fixed-bearing prosthesis in other knee.
Methods: Eighteen patients receiving bilateral TKAs to treat osteoarthritis were included. The synovial fluid was obtained from 36 knees at an average of 3.5 years after the operation. The in vivo polyethylene wear particles were isolated from the synovial fluid using a previously validated method and examined using a scanning electron microscope and an image analyser.
Results: The size and shape of the polyethylene wear particles from the mobile-bearing prostheses were similar to those from the conventional fixed-bearing prostheses. Although the number of wear particles from the mobile-bearing prosthesis (1.63 × 107 counts/knee) appeared smaller than that from the fixed-bearing prosthesis (2.16 × 107 counts/knee), the difference was not statistically significant.
Conclusions: The current in vivo study shows that no statistically significant differences were found between the polyethylene wear particles generated by a newly introduced mobile-bearing PS prosthesis and a conventional fixed-bearing PS prosthesis during the early clinical stage after implantation.
Level of evidence: Therapeutic study, Level III.
Keywords: Fixed-bearing prosthesis; Mobile-bearing prosthesis; Polyethylene wear particle; Total knee arthroplasty.
Similar articles
-
No difference in in vivo polyethylene wear particles between oxidized zirconium and cobalt-chromium femoral component in total knee arthroplasty.Knee Surg Sports Traumatol Arthrosc. 2014 Mar;22(3):680-6. doi: 10.1007/s00167-013-2724-4. Epub 2013 Oct 20. Knee Surg Sports Traumatol Arthrosc. 2014. PMID: 24141905 Clinical Trial.
-
Vitamin E-infused highly cross-linked polyethylene did not reduce the number of in vivo wear particles in total knee arthroplasty.Bone Joint J. 2020 Nov;102-B(11):1527-1534. doi: 10.1302/0301-620X.102B11.BJJ-2020-0413.R1. Bone Joint J. 2020. PMID: 33135435
-
Weight of polyethylene wear particles is similar in TKAs with oxidized zirconium and cobalt-chrome prostheses.Clin Orthop Relat Res. 2010 May;468(5):1296-304. doi: 10.1007/s11999-009-1179-x. Epub 2009 Dec 1. Clin Orthop Relat Res. 2010. PMID: 19949906 Free PMC article. Clinical Trial.
-
No differences between fixed- and mobile-bearing total knee arthroplasty.Knee Surg Sports Traumatol Arthrosc. 2017 Jun;25(6):1757-1777. doi: 10.1007/s00167-016-4195-x. Epub 2016 Jun 20. Knee Surg Sports Traumatol Arthrosc. 2017. PMID: 27324479 Review.
-
Superior Mid- to Long-Term Clinical Outcomes of Mobile-Bearing Total Knee Arthroplasty Compared to Fixed-Bearing: A Meta-Analysis Based on a Minimum of 5 Years of Study.J Knee Surg. 2021 Oct;34(12):1368-1378. doi: 10.1055/s-0040-1709490. Epub 2020 Jun 5. J Knee Surg. 2021. PMID: 32503063
Cited by
-
Magnetic Resonance Safety Evaluation of a Novel Alumina Matrix Composite Ceramic Knee and Image Artifact Comparison to a Metal Knee Implant of Analogous Design.Arthroplast Today. 2023 Jul 23;22:101170. doi: 10.1016/j.artd.2023.101170. eCollection 2023 Aug. Arthroplast Today. 2023. PMID: 37521740 Free PMC article.
-
Load-Dependent Characteristics of Cruciate-Retaining and Posterior-Stabilized Total Knee Arthroplasty: A Biomechanical Study.Clin Orthop Surg. 2024 Aug;16(4):570-577. doi: 10.4055/cios23356. Epub 2024 Jul 12. Clin Orthop Surg. 2024. PMID: 39092300 Free PMC article.
-
Comparison of Patient Satisfaction Between Medial Pivot Prostheses and Posterior-Stabilized Prostheses in Total Knee Arthroplasty.Orthop Surg. 2020 Jun;12(3):836-842. doi: 10.1111/os.12687. Epub 2020 May 10. Orthop Surg. 2020. PMID: 32390346 Free PMC article.
-
[Update 2025: Biomechanics and kinematics after total knee arthroplasty (TKA)].Orthopadie (Heidelb). 2025 Jul 22. doi: 10.1007/s00132-025-04687-8. Online ahead of print. Orthopadie (Heidelb). 2025. PMID: 40694122 Review. German.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical