Towards an optimal paradigm for intraoperative auditory nerve monitoring with auditory steady state responses

Affiliations

Towards an optimal paradigm for intraoperative auditory nerve monitoring with auditory steady state responses

Stefan Rampp et al. J Clin Monit Comput. 2017 Feb.

Abstract

Auditory steady state responses (ASSR) may offer an alternative to brainstem auditory evoked potentials for monitoring of the auditory nerve during surgical procedures. In the current study, we evaluated the influence of noise on ASSR characteristics in total intravenous anesthesia (TIVA). Simulated ASSR in real noise recorded during surgery under TIVA were constructed with known parameters. Influence of amplitude, modulation frequency, averaging sweeps and detection threshold on ASSR were evaluated. High amplitude, more sweeps and a liberal threshold facilitated detection. High amplitude ASSR (80 nV) were detected in up to 45 % with 16 s of data, in 80-90 % with 112 s. Near-threshold ASSR were detected in 0.8-25 %. False positives ranged between 0.3 and 10.3 %. Number of sweeps did not influence false positives. Amplitude errors varied between -61 and +39 % and improved with more averages but not with different thresholds. Modulation rate demonstrated the strongest influence on all parameters. 110 Hz yielded best, 90 Hz the worst results. Choice of parameters strongly influences detection and characteristics of ASSR. Optimal parameters enabled detection after 16 s in 45 %. Due to specific noise characteristics, modulation has a critical impact, which is currently not sufficiently recognized in ASSR studies.

Keywords: Anesthesia; Auditory nerve; Auditory steady state response; Hearing; Intraoperative monitoring.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Int J Audiol. 2004 Dec;43 Suppl 1:S39-43 - PubMed
    1. Clin Neurophysiol. 2003 Jun;114(6):1053-68 - PubMed
    1. Ear Hear. 1992 Oct;13(5):307-10 - PubMed
    1. J Neurol Surg B Skull Base. 2013 Oct;74(5):274-8 - PubMed
    1. Comput Methods Programs Biomed. 2000 Feb;61(2):125-50 - PubMed

LinkOut - more resources