ZIEHL-NEELSEN MICROSCOPY IN THE DIAGNOSIS OF TUBERCULOSIS IN SETTINGS OF HIGH HUMAN IMMUNODEFICIENCY VIRUS PREVALENCE
- PMID: 26852457
ZIEHL-NEELSEN MICROSCOPY IN THE DIAGNOSIS OF TUBERCULOSIS IN SETTINGS OF HIGH HUMAN IMMUNODEFICIENCY VIRUS PREVALENCE
Abstract
Objective: To determine the accuracy of Ziehl-Neelsen microscopy in the diagnosis of TB in setings of high HIV prevalence.
Design: Cross-sectional descriptive study.
Setting: Hospitals serving areas of high human immunodeficiency virus prevalence in western Kenya. The study was conducted between September 2007 and September 2009.
Results: In total, 341/872(39.1%) of the TB suspects were positive in ZN, 53.1% (181/341) of them culture positive. Only 3.8% (20/531) of the ZN smear negatives were culture positive. Of the 695 suspects evaluated for both Mycobacterium and HIV infection, 255 (36.7%) were ZN smear positive, 42.7% of them HIV positive. Out of the 440 ZN smear negatives, 37% were HIV positive. Similarly, 168 suspects were culture positive, 46.4% of them HIV positive. The HIV infection did not significantly reduce ZN smear positivity rate (P = 0.42) and culture sensitivity (P = 0.09). The ZN sensitivity and specificity were 88.1% and 79.7%, respectively. The predictive values were 58.0 (PPV), and 95.5% (NPV), respectively. However, the area under the ROC curve was 0.84, with 95% CI between 0.80-0.87 and P < 0.001). The ZN smear microscopy had a lesser ability to distinguish between TB and non-TB cases compared to culture.
Conclusion: ZN microscopy causes a significant over-diagnosis of TB in settings of high HIV/AIDS prevalence. There is need for further studies on this subject taking into consideration the various confounding factors.
Similar articles
-
Bleach-digested sputum smears for the diagnosis of TB in HIV-infected individuals.Trop Doct. 2007 Jan;37(1):35-6. doi: 10.1258/004947507779952014. Trop Doct. 2007. PMID: 17326886
-
Evaluation of pulmonary tuberculosis case detection improvement with the deployment of XpertMTB/Rif in the tuberculosis control program of cross River State, Nigeria.Int J Mycobacteriol. 2017 Jan-Mar;6(1):94-96. doi: 10.4103/2212-5531.201890. Int J Mycobacteriol. 2017. PMID: 28317812
-
Bleach treatment of sputum samples aids pulmonary tuberculosis screening among HIV-infected patients in Laos.Int J Tuberc Lung Dis. 2011 Oct;15(10):1353-8. doi: 10.5588/ijtld.11.0075. Int J Tuberc Lung Dis. 2011. PMID: 22283894
-
Smear microscopy as a diagnostic tool of tuberculosis: Review of smear negative cases, frequency, risk factors, and prevention criteria.Indian J Tuberc. 2018 Jul;65(3):190-194. doi: 10.1016/j.ijtb.2018.02.001. Epub 2018 Feb 13. Indian J Tuberc. 2018. PMID: 29933859 Review.
-
Usefulness of the polymerase chain reaction dot-blot assay, used with Ziehl-Neelsen staining, for the rapid and convenient diagnosis of pulmonary tuberculosis in human immunodeficiency virus-seropositive and -seronegative individuals.Infect Dis Rep. 2011 Mar 24;3(1):e3. doi: 10.4081/idr.2011.e3. eCollection 2011 Mar 8. Infect Dis Rep. 2011. PMID: 24470902 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical