Hemodynamic Effect of Flow Diverter and Coils in Treatment of Large and Giant Intracranial Aneurysms
- PMID: 26852712
- DOI: 10.1016/j.wneu.2016.01.079
Hemodynamic Effect of Flow Diverter and Coils in Treatment of Large and Giant Intracranial Aneurysms
Abstract
Background: This study aimed to investigate the hemodynamic changes induced by a flow diverter (FD) and coils in the treatment of internal carotid artery aneurysms, as well as to evaluate the effect of this treatment by using angiographic follow-up data.
Methods: Six large and giant aneurysms were treated by the Tubridge FD and loose packing coils between June 2013 and May 2015. Patient-specific models were constructed and analyzed using a computational fluid dynamics (CFD) method. The virtual FD deployment method was used to implant the Tubridge stent into a 3-dimensional digital subtraction angiographic image of the aneurysms, and the coils were simulated by a porous medium model.
Results: Tubridge FD alone can significantly reduce the intra-aneurysmal flow velocity (0.17 ± 0.05 m/s-0.11 ± 0.06 m/s, P < 0.001) and wall shear stress (WSS, 1.39 ± 0.29 Pa-0.77 ± 0.34 Pa, P = 0.001) and increase the low wall shear area (LSA, 6.38% ± 1.49%-34.60% ± 28.90%, P = 0.047). Coils, as a supplementary measure, further reduced the velocity (0.11 ± 0.06 m/s-0.08 ± 0.05 m/s, P = 0.03) and WSS (0.77 ± 0.34 Pa-0.47 ± 0.35 Pa, P = 0.04) and increased the LSA (34.60% ± 28.90%-63.33% ± 34.82%, P = 0.044). Aneurysm with sustained strong inflow after treatment (case 3, 25% reduction in velocity, 12% reduction in WSS, and 16% increment in LSA) showed partial patency, whereas others with a weaker inflow jet (mean 56% reduction in velocity, 74% reduction in WSS, and 1081% increment in LSA) showed complete occlusion at follow-up.
Conclusions: On the basis of using the CFD method, adjunctive coiling with the Tubridge FD placement may significantly reduce intra-aneurysmal flow velocity and WSS, promoting thrombosis formation and occlusion of aneurysms.
Keywords: Aneurysm; Coil; Computational fluid dynamics; Flow diverter; Hemodynamics.
Copyright © 2016 Elsevier Inc. All rights reserved.
Similar articles
-
High-fidelity virtual stenting: modeling of flow diverter deployment for hemodynamic characterization of complex intracranial aneurysms.J Neurosurg. 2015 Oct;123(4):832-40. doi: 10.3171/2014.11.JNS14497. Epub 2015 Jun 19. J Neurosurg. 2015. PMID: 26090829 Free PMC article.
-
Hemodynamic alterations after stent implantation in 15 cases of intracranial aneurysm.Acta Neurochir (Wien). 2016 Apr;158(4):811-819. doi: 10.1007/s00701-015-2696-x. Epub 2016 Jan 8. Acta Neurochir (Wien). 2016. PMID: 26746828 Free PMC article.
-
Sequential Hemodynamic Analysis of Ruptured Posterior Communicating Artery Aneurysms Treated With Coil Embolization and Delayed Flow Diversion.Oper Neurosurg. 2024 Nov 12;29(1):80-92. doi: 10.1227/ons.0000000000001421. Oper Neurosurg. 2024. PMID: 39530693
-
A comparison of 4D flow MRI-derived wall shear stress with computational fluid dynamics methods for intracranial aneurysms and carotid bifurcations - A review.Magn Reson Imaging. 2018 May;48:62-69. doi: 10.1016/j.mri.2017.12.005. Epub 2017 Dec 6. Magn Reson Imaging. 2018. PMID: 29223732 Review.
-
Hemodynamic changes in a middle cerebral artery aneurysm at follow-up times before and after its rupture: a case report and a review of the literature.Neurosurg Rev. 2017 Apr;40(2):329-338. doi: 10.1007/s10143-016-0795-7. Epub 2016 Nov 24. Neurosurg Rev. 2017. PMID: 27882440 Review.
Cited by
-
Morphological and Hemodynamic Parameters for Middle Cerebral Artery Bifurcation Aneurysm Rupture Risk Assessment.J Korean Neurosurg Soc. 2017 Sep;60(5):504-510. doi: 10.3340/jkns.2017.0101.009. Epub 2017 Aug 30. J Korean Neurosurg Soc. 2017. PMID: 28881112 Free PMC article.
-
Treatment Outcome of Flow Diverter Device for Medium-Sized Cerebral Aneurysms: A Single-Center Report.J Neuroendovasc Ther. 2024;18(9):231-239. doi: 10.5797/jnet.oa.2024-0025. Epub 2024 Aug 10. J Neuroendovasc Ther. 2024. PMID: 39309174 Free PMC article.
-
Safety and Efficacy of Coils in Conjunction With the Pipeline Flex Embolization Device for the Treatment of Cerebral Aneurysms.Front Neurol. 2021 Oct 25;12:651465. doi: 10.3389/fneur.2021.651465. eCollection 2021. Front Neurol. 2021. PMID: 34759878 Free PMC article.
-
Evaluating the Tubridge™ flow diverter for large cavernous carotid artery aneurysms.Chin Neurosurg J. 2020 Dec 1;6(1):36. doi: 10.1186/s41016-020-00215-z. Chin Neurosurg J. 2020. PMID: 33292725 Free PMC article.
-
Successful Retreatment of Recurrent Intracranial Vertebral Artery Dissecting Aneurysms After Stent-Assisted Coil Embolization: A Self-Controlled Hemodynamic Analysis.World Neurosurg. 2017 Jan;97:344-350. doi: 10.1016/j.wneu.2016.10.003. Epub 2016 Oct 11. World Neurosurg. 2017. PMID: 27742509 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials
Miscellaneous