Quantitative analysis of MRI-guided attenuation correction techniques in time-of-flight brain PET/MRI
- PMID: 26853602
- DOI: 10.1016/j.neuroimage.2016.01.060
Quantitative analysis of MRI-guided attenuation correction techniques in time-of-flight brain PET/MRI
Abstract
Purpose: In quantitative PET/MR imaging, attenuation correction (AC) of PET data is markedly challenged by the need of deriving accurate attenuation maps from MR images. A number of strategies have been developed for MRI-guided attenuation correction with different degrees of success. In this work, we compare the quantitative performance of three generic AC methods, including standard 3-class MR segmentation-based, advanced atlas-registration-based and emission-based approaches in the context of brain time-of-flight (TOF) PET/MRI.
Materials and methods: Fourteen patients referred for diagnostic MRI and (18)F-FDG PET/CT brain scans were included in this comparative study. For each study, PET images were reconstructed using four different attenuation maps derived from CT-based AC (CTAC) serving as reference, standard 3-class MR-segmentation, atlas-registration and emission-based AC methods. To generate 3-class attenuation maps, T1-weighted MRI images were segmented into background air, fat and soft-tissue classes followed by assignment of constant linear attenuation coefficients of 0, 0.0864 and 0.0975 cm(-1) to each class, respectively. A robust atlas-registration based AC method was developed for pseudo-CT generation using local weighted fusion of atlases based on their morphological similarity to target MR images. Our recently proposed MRI-guided maximum likelihood reconstruction of activity and attenuation (MLAA) algorithm was employed to estimate the attenuation map from TOF emission data. The performance of the different AC algorithms in terms of prediction of bones and quantification of PET tracer uptake was objectively evaluated with respect to reference CTAC maps and CTAC-PET images.
Results: Qualitative evaluation showed that the MLAA-AC method could sparsely estimate bones and accurately differentiate them from air cavities. It was found that the atlas-AC method can accurately predict bones with variable errors in defining air cavities. Quantitative assessment of bone extraction accuracy based on Dice similarity coefficient (DSC) showed that MLAA-AC and atlas-AC resulted in DSC mean values of 0.79 and 0.92, respectively, in all patients. The MLAA-AC and atlas-AC methods predicted mean linear attenuation coefficients of 0.107 and 0.134 cm(-1), respectively, for the skull compared to reference CTAC mean value of 0.138cm(-1). The evaluation of the relative change in tracer uptake within 32 distinct regions of the brain with respect to CTAC PET images showed that the 3-class MRAC, MLAA-AC and atlas-AC methods resulted in quantification errors of -16.2 ± 3.6%, -13.3 ± 3.3% and 1.0 ± 3.4%, respectively. Linear regression and Bland-Altman concordance plots showed that both 3-class MRAC and MLAA-AC methods result in a significant systematic bias in PET tracer uptake, while the atlas-AC method results in a negligible bias.
Conclusion: The standard 3-class MRAC method significantly underestimated cerebral PET tracer uptake. While current state-of-the-art MLAA-AC methods look promising, they were unable to noticeably reduce quantification errors in the context of brain imaging. Conversely, the proposed atlas-AC method provided the most accurate attenuation maps, and thus the lowest quantification bias.
Keywords: Attenuation correction; Brain imaging; PET/MRI; Quantification; Segmentation.
Copyright © 2016 Elsevier Inc. All rights reserved.
Similar articles
-
Emission-based estimation of lung attenuation coefficients for attenuation correction in time-of-flight PET/MR.Phys Med Biol. 2015 Jun 21;60(12):4813-33. doi: 10.1088/0031-9155/60/12/4813. Epub 2015 Jun 5. Phys Med Biol. 2015. PMID: 26047036
-
MR-guided joint reconstruction of activity and attenuation in brain PET-MR.Neuroimage. 2017 Nov 15;162:276-288. doi: 10.1016/j.neuroimage.2017.09.006. Epub 2017 Sep 14. Neuroimage. 2017. PMID: 28918316
-
Clinical Assessment of Emission- and Segmentation-Based MR-Guided Attenuation Correction in Whole-Body Time-of-Flight PET/MR Imaging.J Nucl Med. 2015 Jun;56(6):877-83. doi: 10.2967/jnumed.115.154807. Epub 2015 Apr 9. J Nucl Med. 2015. PMID: 25858043
-
Hybrid Positron Emission Tomography/Magnetic Resonance Imaging: Challenges, Methods, and State of the Art of Hardware Component Attenuation Correction.Invest Radiol. 2016 Oct;51(10):624-34. doi: 10.1097/RLI.0000000000000289. Invest Radiol. 2016. PMID: 27175550 Review.
-
Vision 20/20: Magnetic resonance imaging-guided attenuation correction in PET/MRI: Challenges, solutions, and opportunities.Med Phys. 2016 Mar;43(3):1130-55. doi: 10.1118/1.4941014. Med Phys. 2016. PMID: 26936700 Review.
Cited by
-
From simultaneous to synergistic MR-PET brain imaging: A review of hybrid MR-PET imaging methodologies.Hum Brain Mapp. 2018 Dec;39(12):5126-5144. doi: 10.1002/hbm.24314. Epub 2018 Aug 4. Hum Brain Mapp. 2018. PMID: 30076750 Free PMC article. Review.
-
Deep-JASC: joint attenuation and scatter correction in whole-body 18F-FDG PET using a deep residual network.Eur J Nucl Med Mol Imaging. 2020 Oct;47(11):2533-2548. doi: 10.1007/s00259-020-04852-5. Epub 2020 May 15. Eur J Nucl Med Mol Imaging. 2020. PMID: 32415552
-
Visual detection of regional brain hypometabolism in cognitively impaired patients is independent of positron emission tomography-magnetic resonance attenuation correction method.World J Nucl Med. 2018 Jul-Sep;17(3):188-194. doi: 10.4103/wjnm.WJNM_61_17. World J Nucl Med. 2018. PMID: 30034284 Free PMC article.
-
A Quantitative Evaluation of Joint Activity and Attenuation Reconstruction in TOF PET/MR Brain Imaging.J Nucl Med. 2019 Nov;60(11):1649-1655. doi: 10.2967/jnumed.118.220871. Epub 2019 Apr 12. J Nucl Med. 2019. PMID: 30979823 Free PMC article.
-
PET/MRI in the Presence of Metal Implants: Completion of the Attenuation Map from PET Emission Data.J Nucl Med. 2017 May;58(5):840-845. doi: 10.2967/jnumed.116.183343. Epub 2017 Jan 26. J Nucl Med. 2017. PMID: 28126884 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources