Perrin and Förster unified: Dual-laser triple-polarization FRET (3polFRET) for interactions at the Förster-distance and beyond
- PMID: 26854711
- DOI: 10.1016/j.bbamcr.2016.02.002
Perrin and Förster unified: Dual-laser triple-polarization FRET (3polFRET) for interactions at the Förster-distance and beyond
Abstract
Dual laser flow cytometric energy transfer (FCET)--elaborated by Trón et al. in 1984--is an efficient and rapid way of measuring FRET on large cell populations. FRET efficiency and the donor and acceptor concentrations are determined from one donor and two acceptor signals. In this communication this method is extended towards the domain of receptor dynamics by the detection of polarized components of the three intensities. By enabling a complete description of the proximity and dynamics of FRET-systems, the new measuring scheme allows a more refined description of both the structure and dynamics of cell surface receptor clusters at the nano-scale and beyond. Associated donor fraction, limiting anisotropy and rotational correlation time of the donor, acceptor anisotropy and cell-by-cell estimation of the orientation factor for FRET (κ2) are available in the steady state on a single FRET sample in a very rapid and statistically efficient way offered by flow cytometry. For a more sensitive detection of conformational changes the "polarized FRET indices"--quantities composed from FRET efficiency and anisotropies--are proposed. The method is illustrated by measurements on a FRET system with changing FRET-fraction and on a two donor-one acceptor-system, when the existence of receptor trimers are proven by the detection of "hetero-FRET induced homo-FRET relief", i.e. the diminishing of homo-FRET between the two donors in the presence of a donor quencher. The method also offers higher sensitivity for assessing conformational changes at the nano-scale, due to its capability for the simultaneous detection of changes of proximity and relative orientations of the FRET donor and acceptor. Although the method has been introduced in the context of FRET, it is more general: It can be used for monitoring triple-anisotropy correlations also in those cases when FRET actually does not occur, e.g. for interactions occuring beyond the Förster-distance R0. Interpretation of κ2 has been extended.
Keywords: Acceptor anisotropy; Donor anisotropy; FRET-fraction; Homo-FRET relief; Orientation factor for FRET; Triple-anisotropy correlations.
Copyright © 2016 Elsevier B.V. All rights reserved.
Similar articles
-
Confocal microscopic dual-laser dual-polarization FRET (2polFRET) at the acceptor side for correlating rotations at different distances on the cell surface.Biochim Biophys Acta Gen Subj. 2018 Apr;1862(4):1050-1068. doi: 10.1016/j.bbagen.2017.12.013. Epub 2017 Dec 30. Biochim Biophys Acta Gen Subj. 2018. PMID: 29292190
-
Depolarized FRET (depolFRET) on the cell surface: FRET control by photoselection.Biochim Biophys Acta. 2016 Feb;1863(2):322-34. doi: 10.1016/j.bbamcr.2015.12.003. Epub 2015 Dec 3. Biochim Biophys Acta. 2016. PMID: 26657258
-
Dual-Laser Tetra-Polarization FRET (4polFRET) for Site-Selective Control of Homo-FRET in Hetero-FRET Systems on the Cell Surface: The Homo-FRET Gate.Anal Chem. 2018 Sep 4;90(17):10159-10170. doi: 10.1021/acs.analchem.7b05441. Epub 2018 Aug 22. Anal Chem. 2018. PMID: 30080974
-
Fluorescence anisotropy imaging microscopy for homo-FRET in living cells.Methods Cell Biol. 2008;85:395-414. doi: 10.1016/S0091-679X(08)85017-0. Methods Cell Biol. 2008. PMID: 18155472 Review.
-
Extensive use of FRET in biological imaging.Microscopy (Oxf). 2013 Aug;62(4):419-28. doi: 10.1093/jmicro/dft037. Microscopy (Oxf). 2013. PMID: 23797967 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources